Condition
Motor fails to run.
Pressure Relief Valve opens to
discharge grease.
PowerLuber fails to dispense grease. - Grease tube assembly is out of grease. Check that grease tube assembly has grease.
PowerLuber continues to lose prime. - Air may be trapped in several locations
Battery fails to take a charge.
Form 403155
All manuals and user guides at all-guides.com

TROUBLESHOOTING

Possible Cause
- Battery needs charging.
- Faulty wiring to motor.
- Blocked Line.
- Blocked Bearing
- Blocked Grease Fitting.
- Loss of prime.
- Ball check item 22 is not functioning.
in container after bulk filling.
- Follower may be binding in grease
tube assembly.
- Charger may not have power.
- Battery may be bad.
Corrective Action
Recharge battery.
Remove battery, disassemble handle and
check wiring for loose connection.
Check lines, brazing and grease fitting to
remove or clean obstructions.
Repeat priming operation.
Remove Items 22 and clean and
inspect ball seat area.
Empty grease tube assembly, refill and
repeat priming instructions.
Replace grease tube assembly Item 9.
Check that receptacle has power.
Replace battery.