TFA_No. 31.5010_Anleitung
AIR CO
NTROL UP – CO
2
2
7. Traffic light display
• The CO
monitor shows the CO
2
light display:
CO
value (ppm)
2
400-600
601-1000
1001-1500
1501-2000
2000
8. CO
upper limit
2
• Press briefly the CO
SET button in normal mode.
2
(default) or the last adjusted upper CO
3 seconds, the device automatically returns to the normal mode.
• Press and hold the CO
SET button for 2 seconds to enter the setting
2
mode. The value flashes.
• Press the DOWN/CALIBRATE or UP/°C/°F button to set the desired upper
limit in steps of 10ppm, while the value flashes.
• Press and hold the DOWN/CALIBRATE or UP/°C/°F button in setting mode
for fast mode.
• Confirm the setting with the CO
• The device will automatically quit the setting mode if no button is pressed
for 20 seconds. The setting is saved.
• Press the CO
ALARM button in normal mode, to activate or deactivate the
2
alarm function for the upper CO
the alarm is activated.
• If the measured CO
value is above the upper limit setting, an alarm
2
sounds and the CO
alarm symbol flashes. Press any button to stop the
2
alarm sound. The CO
alarm symbol will continue flashing until the mea-
2
sured CO
value is below the set alarm limit.
2
9. CO
, temperature and humidity maximum and minimum values
2
• Press the MEM button in normal mode.
• You can now read the highest measured values for CO
humidity of the last 24 hours (display MAX).
20
17.08.2021
11:50 Uhr
Monitor
comfort level with an extended traffic
2
Description
GOOD
NORMAL
POOR
SERIOUS
SERIOUS +
and 2000 ppm
limit appear on the display. After
2
SET button.
2
limit.
appears on the display when
2
, temperature and
2
Seite 11
AIR CO
NTROL UP – CO
2
• Press the MEM button again.
• The minimum values measured since the last 24 hours appear on the dis-
play (display MIN.
• Press the MEM button again to return to normal mode. The device will
automatically quit the MAX/MIN mode if no button is pressed for 3 se-
conds.
• Press and hold the MEM button for 2 seconds during the highest or low-
est values are displayed. The values will be deleted (display ----) and reset
to the current state.
10. CO
manual calibration function
2
• For the whole calibration process, place the device in an environment with
a CO
concentration of 400ppm (at an open window or outdoors). Wait
2
a few minutes, then press and hold the DOWN/CALIBRATE button for
2 seconds to enter the manual calibration mode. The CAL symbol flashes.
After 20 minutes the CAL symbol stops flashing, the calibration is com-
pleted and the device returns to normal state. Now you can use the device
again as usual.
• During the manual calibration operation, press the DOWN/CALIBRATE but-
ton to exit the calibration mode.
11. Care and maintenance
• Clean the device with a soft damp cloth. Do not use solvents or scouring
agents.
• Turn off the device if you do not use it. Press the POWER/LIGHT sensor
button for 3 seconds.
• Store the device in a dry place.

12. Troubleshooting

Problem
No display on the device
Monitor
2
Solution
➜ Press the POWER/LIGHT button for
3 seconds to switch on the device
➜ Set the brightness with the POWER/LIGHT
button
➜ Connect the device with USB cable and
power adapter and charge the battery
➜ Check the connection
21