First turning on

FIRST TURNING ON
Settings on boiler (authorized service man only):
Before turn on the corrector for the first time, it is necessary to configure the heating circuit on the
boiler / CM2K module to which the corrector will be connected. On the boiler controller in
Installation -> PIN - > CM2K or Heating circuit for which a digital corrector is defined, in the
Corrector menu, it is necessary to select CSK-Touch, and in the menu Addr. dig. corrector, select
the desired corrector address.
For boilers with a built-in mixing heating circuit (BioTec-L, PST and BioTec Plus), it
is necessary to select Heating, Motor drive and Corrector in the Configuration and
then define the Corrector in the Heating Circuit.
IMPORTANT! Open the table on the boiler controller -> Installation -> (PIN) -> CSK-
Touch -> Info and take a picture (or rewrite) the CSK-Touch WiFi ID and the Address
Codes of the built-in correctors according to their addresses.
Settings on CSK-Touch:
After starting the corrector for the first time, a menu will appear on the first screen to select the
desired corrector language. The desired language of the corrector doesn't have to be the same as
the language on the boiler. To select the desired corrector language, press the flag of the desired
language on the screen.
The screen must not be pressed (with your finger ...) when connecting the room
corrector to the el. power supply. If the screen of the corrector is pressed on arrival the
el. power supply (the screen shows 'Firmware update'), the corrector enters the
firmware update mode which can only be used by authorized serviceman. If the
screen is accidentally pressed, it is necessary to turn off the power on the corrector
and turn it on again without ever pressing the screen to get the corrector ready for use.
After selecting the language on the home screen, the indicator flashes that the corrector is not
connected to the boiler (NO CONNECTION!). The corrector is adjusted in the Menu -> Settings.
In menu 3.1.1. Connection type, select the method in which the corrector will be connected to the
boiler / CM2K module. The corrector can be connected in 3 ways:
- WIFI BOX Tree: wireless connection to the boiler via CM-WiFi box. It is necessary to bring power
(230V) to the corrector.
- Home router: wireless connection to the boiler via a home router (if the signal from the CM-WiFi
box is not strong enough). It is necessary to bring power 230V to the corrector.
- Wired: via 2-wire cable connected to CM2K module (D.COR1 or 2, watch out for poles)
Technical instructions CSK-Touch
Corrector software
version