Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Position indicator PA90

Mounting

Contact cable
Punch mark
pushing rod
Head
picture 1
The position contact must be inserted into the cable duct that is glued onto the housing of the linear actuator and it can
be pushed into any position as desired. After then the position contact is fixed with hot glue
Attention: The punch mark at the head of the pushing rod must be aligned with the cable
exit so that the solenoid can actuate the contact
End position window completely open:
Extend the pushing rod completely, push the position contact slowly away from the front end until it switches, and then
push it further away by approx. 5 mm.
End position window completely closed:
Retract the pushing rod completely, push the position contact slowly away from the rear end until it switches, and then
push it further away by approx. 5 mm.
picture 2
Note: While the linear actuator is extended, the position contact will be actuated twice (picture 2).
When the solenoid approaches the contact, the contact will switch on.
When the solenoid continues to move (approx. 12 mm), the contact will switch off for approx. 5 mm and
then on again for approx. 12 mm.
This must be taken into consideration during the configuration of the electronic evaluation system.
If the contact is used for signalling an end position, it only provides an ON signal when the position is correct.
Observe the closing of the contact by way of a continuity tester.
8
Motor cable
Position contact
Front end
ca. 3500mm
OFF
cable duct
Solenoid
Rear end
25mm
Position contact
ON
OFF
ON
OFF
12mm
12mm
5mm
cabel exit
Solenoid
01/13424999496