Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - Beper P303MED001 Bedienungsanleitung

Infrarot-multifunktionsthermometer
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 22
Dimension
Weight
Batteries
Battery life
Ingress protection rating

Troubleshooting

Error
Problem
Er1
Measurement taken befo-
re thermometer is ready
Er2
The room temperature
is not within the range
between 10°C and 40°C
(50°F ~ 104°F)
Er3
The thermometer is not
correctly placed.
Er4
The thermometer detects
a rapid change in the
room temperature
Er5
The thermometer is not
functioning properly
Hi
In forehead mode:
measured temperature
is higher than 43.0°C
(109.4°F)
In object/surface mode:
measured temperature is
higher than 100°C (212°F)
Lo
In forehead mode:
measured temperature
is lower than 34.0°C
(93.2°F)
In object/surface mode:
measured temperature is
lower than 0°C (32°F)
Low battery
153*41*44 mm
approx 84 g (with batteries)
DC3V (2ň batterieAAA)
approx 1 year / 6000 readings
IP22
Solution
Take temperature when the symbol
or appears on the display
Place the thermometer in a room for
at least 30 minutes with a temperature
between 10°C and 40°C (50°F ~ 104°F)
Refer to "Instructions for use" paragraph
for correct use and proceed with a new
reading
Allow the thermometer to rest in a room
for at least 30 minutes at room tempe-
rature between 10°C and 40°C (50°F ~
104°F) before taking the temperature
Remove batteries, wait 1 minute and
place batteries back in the battery
case. If the error message still appears,
contact distributor
Refer to "Istructions for use" paragraph
for correct use and proceed with a new
reading
Refer to "Istructions for use" paragraph
for correct use and proceed with a new
reading
Replace the batteries
13
EN

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

T238

Inhaltsverzeichnis