  • Seite 1 Solar Monitoring VSN800 Weather Station Product Manual...
  • Seite 2 For more detailed information regarding proper installation and use of this product, refer to the product manual located at www.fimer.com. ATTENTION –...
  • Seite 3: Inhaltsverzeichnis

    3.3.2 Plane-of-Array Irradiance (VSN800-14 Model Only) 3.3.3 PV Temperature Sensors 3.3.4 Anemometer 4. Wiring instructions for the VSN800 series 5. Connect to the monitoring or management system 6. Connect secondary sensors (VSN800-14 model only) 7. Connect PV panel sensor (VSN800-12 only) 8.
  • Seite 4: Vsn800 Weather Station

    The VSN800 Weather Station is SunSpec compliant and uses a 2-wire half duplex serial port for Modbus communication to a host. Contact FIMER if you need to modify or program the unit or change the Modbus...
  • Seite 5: Vsn800 Series Installation Overview

    2. VSN800 series installation overview 2.1 VSN800-14 2.2 VSN800-12...
  • Seite 6: Installation Steps

    Mounting Hardware Pyranometer Tripod or pole mount base Ambient Temperature Sensor Guy wire kit, if necessary External PV Panel Temperature Sensor 24VDC Power External Second Pyranometer (VSN800-14 Model Only) Twisted Pair Wires Wind Speed and Wind Direction Sensor (VSN800-14 Model Only)
  • Seite 7: Site Selection And Mounting

    Secure the support mast to the assembly. Lining up the two holes in each mast prevents rotation. At this point the entire unit should be secured to the support structure. It is crucial that the device be oriented as precisely as possible. For the VSN800-14 version, the wind direction measurement is directly related to this positioning.
  • Seite 8: Global Irradiance

    -0.125°C must be taken into account. 3.3.4 Anemometer The anemometer is directly attached to the top of the sensor assembly. For correct wind direction operation the VSN800-14 must be oriented correctly. By default the weather station is configured for operation in the Northern hemisphere. This requires that the irradiance sensor faces due south.
  • Seite 9: Wiring Instructions For The Vsn800 Series

    4.2 Southern hemisphere adjustment For the VSN800-14 model, if you are in the southern hemisphere, the jumper at J11 must be set to Southern. If you are in the northern hemisphere, no adjustment is required. J11 is located in upper left section of the circuit board.
  • Seite 10: Connect To The Monitoring Or Management System

    5. Connect to the monitoring or management system The Modbus (RS485) connection is same as with any other RS485 device connected to a SunSpec-compliant management system. Refer to your management system documentation of any unique installation requirements. 1. String cable between the weather station and the management system to complete the physical connection. The connection to the management system can be as a single RS485 device or as part of a daisy chain of RS485 devices.
  • Seite 11 0004 0004 C_SunSpec_Length uint16 registers N/A Length of common model block 0005 0020 C-Manufacturer String(32) N/A “FIMER” Well-known value “VSN800-12” or 0021 0036 C-Model String(32) N/A Manuf specific value “VSN800-14” 0037 0044 C-Options String(16) N/A “0” Manuf specific value...
  • Seite 12 Scale Start Name Type Units Contents Description Factor SunSpec Back of Module Temperature Registers Well-known value. Uniquely identifies 0090 0090 C_SunSpec_DID int16 this as a SunSpec Back of Module Temperature Mode Variable length model block =(5*n), 0091 0091 C_Sunspec_Length int16 where n=number of sensors blocks 0092 0092 E_BOM_Temp_1...
  • Seite 13: Connect Secondary Sensors (Vsn800-14 Model Only)

    GND. Connect the PV Panel temperature sensor cable to the two terminals labeled PV Temp #1. 6.1 Weather Station Electronics Board, Connect Secondary Sensors (VSN800-14 Model) The Pyranometer sensors are not interchangeable. The Pyranometer sensor supplied with the weather stations must be wired to Pyranometer #2.
  • Seite 14: Connect Pv Panel Sensor (Vsn800-12 Only)

    1. Attach the PV panel temperature sensor so it registers the temperature on the backside of a PV panel. See Sensor Mounting Requirements for location and mounting considerations. 2. Connect the sensor to the proper location on the circuit board. Note that the PV Temp #2 connectors are not used for the VSN800-12 Model.
  • Seite 15: Complete The Installation

    8. Complete the Installation 1. Properly ground the weather station by connecting the Earth GND terminal at the Weather Station to an earth ground. Connecting the Earth GND helps ensure the accuracy of weather instruments. 2. Re-attach the cover to the connection case using the four screws. Make sure not to pinch the newly connected 24VDC or RS485 wires coming out of the case bottom.
  • Seite 16: System Activation And Validation

    9. System activation and validation If you acquired the VSN800 series as part of a product bundle, please refer to the information that came with your VSN750 series package. This information will describe the next steps for product installation and system validation.
  • Seite 17: Hardware Specifications

    11. Hardware Specifications Power Specifications: Power Requirements: 10 to 30VDC at 50mA Operating Environment: Temperature: 40°C to 60°C (-40 to 140°F) Humidity: 0-100% Condensing Pyranometer Sensors: Range: 0 to 1750 W/m2 Accuracy: +/-5% Cosine Response 45° +/-1% Cosine Response 75° +/-5% Operational Temperature: 25 to 55°C (-13 to 131°F)
  • Seite 18 ENGLISH ITALIANO DEUTSCH ESPAÑOL FRANÇAIS The symbol of the crossed-out wheeled bin Il simbolo del contenitore di spazzatura Mit dem Symbol der ausgekreuzten Mülltonne El símbolo del contenedor de basura tachado Le symbole de poubelle interdite identifie les identifies electrical and electronic equipment su ruote barrato, accompagnato da una werden Elektro-...
  • Seite 19 ČESKY ΕΛΛΗΝΙΚΆ POLSKI SLOVENČINA SLOVENŠČINA Symbol přeškrtnuté popelnice na kolečkách Το σύμβολο με τον διαγεγραμμένο τροχήλατο Symbol przekreślonego kosza na śmierci Symbol preškrtnutej odpadkovej nádoby na Simbol prečrtanega koša za smeti na kolesih označuje elektrické a elektronické zařízení κάδο προσδιορίζει ηλεκτρικό και ηλεκτρονικό na kółkach na sprzęcie elektrycznym i kolieskach označuje elektrické...