To set the scale press SET button. There are 9 available scales:
1. Concrete (0-6%H2O)
2. Cement Screed (0-6%H2O)
3. Cement Screed (0-4% CM)
4. Anhydrite Screed (0-3.5% H2O)
5. Anhydrite Screed (0-1.9% CM)
6. Caisson 0.3-15.3 Scale (0.3-15.3m)
7. Relative Scale (0-100%)
8. Wood type scale into % Wood moisture
9. Resistance measurement Ohm - Scale
Name of chosen scale will appear in the scale indicator field.To see detailed description of each
scale go to Available scales section.
Measurement Range:
Function
!!! Only IR version !!!
Embedded Surface
Temperature
To set the mode of measurement press ON/HOLD button. There are 2 available modes:
Normal, Max Hold
The display color will change depending on which mode was chosen.
To see detailed description of each mode go to Modes & functions section.
• To make a measurement press the meter against the tested surface until all spring
electrodes are completely blocked.
Caution: Do not press the device too intensely as this may harm the electrodes.
Caution: Fingers SHOULD NOT touch the sensor plate and electrodes while measuring.
The meter should be held in the middle while measuring.
Range
-30 ~ +250°C
Accuracy
±0,3°C
Sensortype
Infrared