INSTALLATION

P6010 PCC can be mounted in any desired angle. Make sure that the
deaeration port is not blocked. If blocked, it will deteriorate the function of
the PCC.
The design of the PCC requires that the incoming pressure is 0.2 MPa [29 psi]
higher than the output pressure. Valid for max flow, lower flows require lower
differences.
Note: The quality of the compressed air must meet the DIN ISO 8573-1
class 4 requirements.
Check that correct hose dimensions are used, so that no pressure drops are
caused. Avoid using long hoses, angled couplings and sharp bends.
DIN ISO 8573-1
Class
Particle
size
max. in μm
1
0.1
2
1
3
5
4
15
5
40
6
7
The P6010 PCC should always be connected to a stabilized 24 V power
supply and an external control voltage (setpoint). The unit is controlled either
by an external control unit (a PLC, for example) or by a simple potentiometer.
The controlling unit must be able to supply a 0–10 V signal for the setpoint
value.
If a potentiometer is used for control, it should be connected according to
the schematics. The position of the potentiometer sets the setpoint value.
4
Particle
Water
density
max. in mg/
Pressure dew
point in °C
0.1
-70
1
-40
5
-20
8
10
Water
Water g/m³
0.003
0.117
0.88
3
5.95
7
7.73
10
9.36
Cannot be specified.
Oil
Residual oil
content in mg/m³
0.01
0.1
1
5
25

Werbung