Herunterladen Diese Seite drucken

Schlegel ASI SAW16A Betriebsanleitung (Original Seite 4

As-interface-notaus-taster

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

( T r a n s l a t i o n o f t h e o r i g . O p e r a t i n g I n s t r u c t i o n s )
AS-Interface Emergency-Stop Slave
Safety at Work
Installation:
ASI_SAW16(A), ASI_SAW22(A)
Put slave and E-STOP together
Dimensional Drawings: (all dimensions in mm)
16mm models:
ASI_SAW16A, ASI_SAW16E
22mm models:
ASI_SAW22A, ASI_SAW22E
*1) refers only to the types ASI_SAW16A, ASI_SAW22A
*2) refers only to the types ASI_SAW16A, ASI_SAW22A (with additional addressing jack)
Georg Schlegel GmbH & Co. KG
Kapellenweg 4
D-88525 Dürmentingen
Make sure to use the
correct polarity !
blue:
ASi -
brown:
ASi+
1
*
1
*
2
*
1
*
2
*
Tel.: 0 73 71 / 502 – 0
Fax: 0 73 71 / 502 – 49
e-mail: info@schlegel.biz
ASI_SAW16A, ASI_SAW16E
ASI_SAW22A, ASI_SAW22E
Insatallation:
ASI_SAW16E, ASI_SAW22E
Put slave and E-STOP together
Connection to AS-Interface
via a 2-pole connector
Models and Accessories
Ref. No.
Description
ASI_SAW16E
AS-i safety slave for E-STOP (16 mm mounting dia.)
AS-i safety slave for E-STOP actuators (22 mm mounting
ASI_SAW22E
dia.)
AS-i safety slave for E-STOP actuators (16 mm mounting
ASI_SAW16A
dia.), with safety shutdown, addressing jack and digital
output
AS-i safety slave for E-STOP actuators (22 mm mounting
ASI_SAW22A
dia.), with safety shutdown, addressing jack and digital
output
Connecting cable between dig. output of ASI_SAW16(A),
VK_JST025BKL
ASI_SAW22(A) and E-STOP actuators with illuminated anti-
lock collar, length approx. 10 cm
Connecting cable between dig. Output of ASI_SAW16(A),
VK_JST034
ASI_SAW22(A) and e.g. an external pilot light; open end,
length approx.. 10cm
Hand tool to press the single conductors "ASI_SL2AWG18"
ASI_MRT
into the IDC connector "ASI_SB2AWG18"
Addressing cable to address the slaves with commercial
ASI_PK500M12
AS-I hand addressing device!
Flexible equipment wire, 2-core cable, brown/blue, to
ASI_SL2AWG18
connect the slaves to the AS-Interface by insulation
piercing.
Flat cable branch, transition from the flexible equipment
LA9Z-SNTB
wire "ASI_SL2AWG18" to the yellow AS-i profile line
SachNr.: BetrAnl_SAWxxx_E_V10_200828.doc
V10, 28.08.2020, Ref.No. 615408100
www.schlegel.biz
Make sure to use
the correct
polarity before
pressing in!
blue:
ASi -
brown:
ASi+
... and snap them into place
by a clockwise rotation
Seite 2 von 2

Werbung

loading

Diese Anleitung auch für: