To set the scale press SET button. There are 7 available scales:
•
1. Concrete (0-6%H2O)
2. Cement Screed (0-6%H2O)
3. Cement Screed (0-4% CM)
4. Anhydrite Screed (0-3.5% H2O)
5. Anhydrite Screed (0-1.9% CM)
6. Caisson 0.3-15.3 Scale (0.3-15.3m)
7. Relative Scale (0-100%)
Name of chosen scale will appear in the scale indicator field.To see detailed description of each
scale go to Available scales section.
To set the mode of measurement press ON/HOLD button. There are 2 available modes:
•
Normal, Max Hold
The display color will change depending on which mode was chosen.
To see detailed description of each mode go to Modes & functions section.
To make a measurement press the meter against the tested surface until all spring
•
electrodes are completely blocked.
Caution: Do not press the device too intensely as this may harm the electrodes.
Caution: Fingers SHOULD NOT touch the sensor plate and electrodes while measuring.
The meter should be held in the middle while measuring.
Wolff GmbH & Co KG | D-74360 Ilsfeld | Ungerhalde 1 | Fon: +49 (0)7062-91556-0 | Fax: +49 (0)7062-91556-41 |
www.wolff-tools.de