OPERATING

SAFETY NOTES
!

INTENDED USE

Using this device in an enclosed area is DANGEROUS
and PROHIBITED.
For
CAUTION:
outdoors
or
in
ventilated areas.
In the
case of a well ventilated
area, at least 25 % of
the enclosure area must
be open. The enclosure
area is the total of all walls. According to applicable
regulations, the device must be installed and the
liquid gas cylinder used.
The installation area must have a minimum volume
of 20 m³ per 1 kW of installed nominal heat input
of the fire pit and be well ventilated (covered patio,
beer tents, etc.).
This device must be installed per these instructions.
The fire pit must not be used in residential,
basement and office spaces or similar spaces.
The fire pit may only be operated using an
interconnected
pressure
permissible output pressure (see Type plate and
factory preset).
Only use the types of gas and gas cylinders
recommended by the manufacturer!
The gas cylinder should be in the designated
enclosure when operating the device.
CAUTION: The glass becomes very hot during
use. If the screen on the device splits or breaks,
do not touch with bare hands. Immediately shut
off the gas supply, remove all shards with tools to
prevent injuries, and contact the manufacturer for
a replacement screen.

FIRE AND EXPLOSION HAZARD

The device must be placed on a level, firm base.
We recommend using a suitable mat to protect the
flooring.
In high winds, ensure the device does not tip.
use
well
regulator
with
Verify the gaskets on the cylinder valve are in place
and in good condition (no damage) before every
use. Do not use additional gaskets.
Never kind the gas hose.
The remaining distance to flammable objects must
not be less than 1 m.
Protect liquid gas cylinder from strong sunlight
(< 40°C).
Maintain
a
materials and substances during use. The
distance in the radiation direction between
the
radiating
substances must not be less than 2 m.
Do
not
cover
for the liquid gas cylinder. Any escaping
gas would build in the container, posing an
explosion hazard.
Do not move the device during use.
Remove the gas cylinder before moving the device.
Repairs and maintenance of gas-related parts of the
a
device must be carried out by authorised specialists.
Always immediately shut off the valve of the gas
cylinder if a malfunction occurs.
Shut off the valve of the liquid gas cylinder or the
pressure regulator after use.
Check the gas hose for cracks and damages before
every use.
The hoses must be replaced within the prescribed
periods.
The gas hose and the pressure regulator must be
replaced by a specialised company at least every
10 years.
If the gas hose is damaged, replace with a gas
hose of the same quality and length, not to exceed
150 cm.
Do not use the device if there is a gas leak. The
gas supply must be shut off if this occurs during
use. Check the device and replace damaged parts
before using it again. Tighten any lose connections.
Close the valve of the liquid gas cylinder or the
pressure regulator before moving the device.
Check
all
connections
installation. Use a foaming agent (e.g. gas control
spray or soapy water).
28
safe
distance
to
flammable
surface
and
flammable
the
vents
of
the
for
leaks
following
housing