Herunterladen Diese Seite drucken

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Network Cable Tester
Check for UTP, STP, and
Modular Cables
WS001
Safety Instructions
Put the device always on a stable and straight surface. Falling will damage the device.
The device must not be placed in direct sunlight or in places with high temperature. This will
damage the device or shorten its lifespan.
Don't place it near heat sources like radiators or other heat producing devices.
Don't expose the device to water, moisture or high humidity.
Don't place it next to a sink or the bathroom. Avoid direct contact with water.
Don't try to open the device.
Prior to the first use of our product make a backup of your data.
In the case of improper use, we are not liable for any loss of data.
In any case, liability for loss of data is limited to the effort that is necessary to restore from
existing backup copies.
Congratulations on the Purchase of WS001
Please read the manual and safety instructions before using the product for the first
time. Otherwise damage may result.
According to the European WEEE directive, electrical and electronic equipment must not be disposed
with consumers waste. Its components must be recycled or disposed apart from each other. Otherwise
contaminative and hazardous substances can pollute our environment.
You as a consumer are committed by law to dispose electrical and electronic devices to the producer,
the dealer, or public collecting points at the end of the devices lifetime for free. Particulars are regulated
in national right. The symbol on the product, in the user's manual, or at the packaging alludes to these
terms. With this kind of waste separation, application and waste disposal of used devices, you achieve
an important share to environmental protection.
The CE Mark confirmed that this product meets the main requirements of the Directive 2014/30/EU
of the European Parliament and the Council of Europe concerning telecommunications and terminal
regarding the safety and health of users and of electro-magnetic interference compliance.
The CE has been demonstrated. These statements are deposited by the manufacturer.
Instruction
· Test function for cables with RJ45, RJ12 and RJ11 plug
· Auto-Scan and step by step testing
· Test modes:
Loop-back: for testing and localizing of laid network of communication cables
Continuity: for continuity testing of network or communication cables
Open: for localizing of disconnected single wires
Shorts: locating of short-circuited single wires
Miss-wire: identification of non-conform wire assignment
Pin to pin configuration: 1 assignment testing
· Main device with one RJ45 female connector and one RJ11/12 female connector
· Remote unit with one RJ45 female connector and one RJ11/12 female connector
· Various LEDs for status display
· Operates with 9 Volt block battery (not included)
· Included a black zipper bag
Functions
Network Cable Tester can test RJ11,RJ12 and RJ45 cables to judge wrong connection, short
circuit and open circuit.
Operation
1. Open the battery compartment at the back of the cable tester and insert a 9V battery (not
included). Close the battery compartment and the tester is ready for use.
2. Switch the tester on (set it to „on" for Automatic mode" or to „S" for the „Slow automatic
mode".) The Power LED indicator will light up and flash as Figure 1.
Switch on the tester:
Off - Power Off
On - Power On for Automatic Mode
S - Slow for Slow Automatic Mode
3. Plug one end of the cable into the transmit connector of the main tester. Plug the other
end of the cable into the receiving connector of the Remote tester.
4. The wires will be now tested, one after another. The tester will switch from one wire to
the other automatically. Please refer to Figure 2. In this way the wiring can be quickly
checked on the display of the Remote terminator test outcome indicators.
Main tester:
1-2-3-4-5-6-7-8-G
Remote tester:
1-2-3-4-5-6-7-8-G (RJ45)
1-2-3-4-5-6 (RJ12)
1-2-3-4 (RJ11)
EN
User Manual
5. If the cable is wired in a wrong way, the test outcome indicators will ight up synchronously
in the following sequence. Following are abnormal connections for reference:
a) Open circuit on certain wire:
* Suppose wire No.3 is open circuited, neither of No.3 LED on the main tester nor on remote
tester would light up.
* If multiple wires are open circuited, all corresponding LED on the main tester and on
remote tester would not light up.
* If less than two wires are connected, none of the LED lights would light up.
b) Short Circuit:
* Suppose there are two wires short circuit between wire No.4 and wire No.5, both of LED
No.4 and No.5 of remote tester will light up weakly, while main tester unchanged.
* Suppose there are three wires short circuit between wire No.4, wire No.5 and wire No.6,
corresponding LED of remote tester would not light up while main tester unchanged.
* There is a simple way to test short circuit: connect one end to main tester, if No.4 and No.5
are light up, it means there's a short circuit between wire 4 and wire 5.
c) Wrong connection:
* If two ends of a cable are disordered, for example wire No.2 and No.4 mis-wired, then
displays on Main Tester will be
1-2-3-4-5-6-7-8-G
Remote Tester will be 1-4-3-2-5-6-7-8-G
So you can see wire 2 and wire 4 are mis-wired.
Warning
1. This cable tester can not test any electrified product.
2. 9V reduplicated battery is used in this tester. If any LED light appears weakly, please
change the battery.
3. Test can not be done while RJ45's Pin are not complety cromped well. Any disobeys may
lead to a permanent damage of the tester.
4. Please use high quality tools to crimp cables.
WARNING
This tester is not intended for use on powered circuits. Attaching this tester to a powered
circuit can result in damage to the tester or injury to the user!
- Do not use this tester with its case open, or parts removed.
Doing so may damage the tester and/or injure the user.
- When using this tester in schools and workshops, responsible teachers or skilled
personnel must control the usage of this tester. Failure to observe this precaution may
result in damage to the tester or injury to the user.
- Follow the recommendations of any Trade Organizations or Regulatory Agencies whose
scope encompasses the use of this tester. Failure to do so may result in damage to the
tester or injury to the user.
- Do not open this tester for maintenance without first disconnecting it from all eternal
circuitry. Failure to observe this precaution may result in damage to the tester or injury to
the user.
- Do not touch the ends of the cables when making tests. An unexpected dangerous
potential may be present. Failure to observe this precaution may result in damage to the
tester or injury to the user.
- Do not apply voltage or current to any of the tester's connectors. Doing so may damage
the tester and/or injure the user.
- This tester must not be used by children. Failure to observe this precaution may result in
damage to the tester or injury to the user.
- Do not use this tester to make measurements in adverse environments such as rain, snow,
fog or locations with steam, explosive gases or dust.
- Do not use the tester in condensing atmospheres. Do not use tester in conditions with
ambient temperature to avoid humidity and condensation of water inside the tester.
- Do not use this tester if it is wet, either from exposure to the weather or after cleaning the
case of the tester.
- Do not attempt immidiate use of the tester when bringin it from a cold environment to a
warm environment. Condensation of water inside and outside may produce dangerous
measuring conditions. Allow the tester to reach room temperature before using.
- Do not modify this tester. Changing the design could make the tester unsafe and this may
result in injury to the user.
- Do not use this tester if it has undergone long-term storage under unfavorable conditions.
- Do not use this tester if it has been damage in transport.
- Avoid usage near strong magnetic fields (magnets, loudspeakers, transformers, motors,
coils, relays, contactors, electromagnets, etc.) The tester may display readings that are in
error.
- Avoid usage near strong electrostatic field (high voltage power lines, television, computer
monitors, etc.) The tester may display readings that are in error.
- Avoid usage near strong RF fields (radio or television transmitters, walkie talkies, cellular
phones, etc.) The tester may display readings that are in error.
- Remove the battery when the tester may be left unused for longer than one month.
Chemical leakage from the battery could damage the tester.
- Do not use the tester if there is evidence of chemical leakage from the battery.
Networking tool set includes:
Crimping Tool for Modular 8P8C Plug
LSA Punchdown Tool
Stripping for Flat Communication cable
Test function for cables with RJ45, RJ12 and RJ11 Plug

Werbung

loading

Inhaltszusammenfassung für B.E.S.T-Germany WS001

  • Seite 1 Main Tester will be 1-2-3-4-5-6-7-8-G Remote Tester will be 1-4-3-2-5-6-7-8-G Congratulations on the Purchase of WS001 So you can see wire 2 and wire 4 are mis-wired. Please read the manual and safety instructions before using the product for the first time.
  • Seite 2 Bedienungsanleitung Netzwerk Kabeltester Prüfung von UTP, STP und Modularkabeln WS001 5. Fehlerhafte Verbindungen werden dann von den LED‘s angezeigt. Im Anschluss finden Sie Beispiele für fehlerhafte Verbindungen: a) Aderunterbrechung Wenn eine Ader, zu,m Beispiel Ader Nr.3 unterbrochen ist, Leuchten die Lichter von Nr.3 weder auf der Master-, noch auf der Remoteeinheit.