The
Tara LED rigid bar is only suitable for installation
in dry indoor rooms.
Risk of electric shock!
There is no warranty coverage for any lights installed
without observing european safety directives. Switch off
voltage before installation. Ensure that the voltage cannot
be accidentally turned on again.
Caution!
Only connect the
Tara LED rigid bar to a
suitable power supply (12 V DC) (in scope of delivery).
Connect
Tara LED rigid bar in parallel.
Scope of delivery
2 x
Tara, LED rigid bar
4 x mounting clip
4 x screw
1 x end cap
1 x power connector - female
1 x plug power supply - male
1 x DimmerswitchTouch male-female
Technical data
Power supply
12 V power supply with constant
output voltage
Power
2 x 5 W
Current strength
2 x 0,41 A
Beam angle
90°
Quantity LED
2 x 84
Length
maximum 2 metres per connection
Dimensions
512 x 12,6 x 10 mm
Compliant with the applicable
european CE directives
Safety class 3 - low voltage protection
Suitable for indoor use only, IP 40
Leuchten für feuergefährdete Betriebs -
stätten. Temperatur der waagerechten
Oberflachen
bei
maxi mal 90° C. Glasoberflächen von
Leucht stofflampen maximal 150° C.
Installation instruction:
1. Mounting clip
1. Pull a parallel string where the LED rigid bar will be installed
(figure 1).
Surface on which the LED rigid bar is installed (inverse, vertical,
horizontal or 90° vertically
2. Fix mounting clips on the base line and the distance depend
on practical situation (figure 2 + 3).
3. After the mounting clip is fixed, snap the groove of he LED
rigid bar bottom into the clip (figure 4 + 5).
2. Magnetic holder instruction
Using the magnets on the back, the LED rigid bar can easily
be attached to any magnetic surface.
As soon as the first LED rigid bar is in the correct position,
further LED rigid bars can be connected. Connection before
the finished installation is not permitted. A maximum of
2 metres
normalem
Betrieb
connection.
baseline for
assembly
Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
magnets
magnetic
surface
Tara can be realized with one
Connecting several LED rigid bars and power supply
1. Snap the front plug into wire socket from top down, when
connect another LED rigid bar, the end cap need to be
removed.
2. Snap the front plug of the second strip into the first LED
rigid bar, then connected in turn.
3. When the last LED rigid bar has been connected, the end
cap can be snapped on from the top.
4. As last step, install the Dimmerswitch Push between
power connector and plug power supply by male and female
plugs.
Disposal
Dispose of electrical and electronic equipment in an
environmentally friendly manner. Please contact your local
council for further information.