Instructions for installation

4. Installation

4.1. Installation location

Mount the device outside the sauna cabin at a height of 1.70 m in a location
free of extraneous heat. In order to guarantee a peaceful and noise-free sauna
session, we recommend that the device is not mounted to the sauna cabin wall if
this can be avoided. The installation must be performed by a licensed electrician
in accordance with VDE 0100, Part 703.
4.2. Installation
WARNING!
Risk of electric shock
● Disconnect the device from the power before removing the housing
cover.
Mount the device with the half-round wood screws provided (see Fig.1).
Fig.1
S2-18
4x25
4x25
4x25
4x25
4x25
4x25
p. 6/12
S2-30
4x25
4x25