Herunterladen Diese Seite drucken

Werbung

EN
DE
NL
NO
Installation
Installation
Installatie, Installasjon
t<45mm
t
F16 T
F16 L
v1.4
80032
20˚- 60˚
Clearline
fusion
viridian
s o l a r
R

Werbung

loading

Inhaltszusammenfassung für Viridian solar Clearline fusion F16 T

  • Seite 1 Clearline fusion Installation Installation Installatie, Installasjon t<45mm 20˚- 60˚ F16 T viridian F16 L s o l a r v1.4 80032...
  • Seite 2 Clearline fusion 1640 n x m 1640 x = 260 + (m x 992) + ([m-1] x 30) y = 505 + (n x 1640) + ([n-1] x 5) 1640 1640 1640 n x m x = 260 + (m x 1640) + ([m-1] x 30) y = 505 + (n x 992) + ([n-1] x 5)
  • Seite 3 Clearline fusion Mechanical Specification Thickness Static roof loading (distributed) kg/m 12.9 Characteristic Wind Resistance 5.32 Ultimate Wind Design Load 5.32 Positive Design Load (IEC61215) 5.40 ) / AA Fire Rating (EN 13501-5 / BS 476-3) ROOF Power Warranty % rated 90%10 years, 80% 25 years Standards IEC61215, 61730, TUV, MCS012...
  • Seite 4 Clearline fusion 1 x 2 1 x 4 Clearline PV16 Clearline PV16 F16-TL F16-TL F16-TC F16-TR F16-TR 2 x 3 2 x 2 Clearline PV16 Clearline PV16 F16-TL F16-TL F16-TC F16-TC F16-TR F16-TR F16-TY F16-TY F16-J F16-J 2 x 1 2 x 4 Clearline PV16 Clearline PV16...
  • Seite 5 Clearline fusion 1 x 2 1 x 4 Clearline PV16 Clearline PV16 F16-LC F16-LL F16-LL F16-LR F16-LR 2 x 3 2 x 2 F16-LR Clearline PV16 F16-LR Clearline PV16 F16-LY F16-LL F16-LY F16-LL F16-LJ F16-LC F16-LJ F16-LC 2 x 1 2 x 4 Clearline PV16 VAL16...
  • Seite 6 Clearline fusion...
  • Seite 7 Clearline fusion Portrait Clearline PV16 Tile support Sill flashing Rafter bracket Lower side flashing Combi rafter bracket Upper side flashing Batten bracket Top flashing Combi batten bracket Joining strip Gutter fixing strip Lower gutter Side fixing tab Lower gutter cover Nail Upper gutter 4 x 25mm screw...
  • Seite 8 Clearline fusion...
  • Seite 9 Clearline fusion Landscape Clearline PV16 Tile support Sill flashing Rafter bracket Lower side flashing Combi rafter bracket Upper side flashing Batten bracket Top flashing Combi batten bracket Joining strip Gutter fixing strip Lower gutter Side fixing tab Lower gutter cover Nail Upper gutter 4 x 25mm screw...
  • Seite 10 Clearline fusion Electrical Electrically test each solar panel as it is installed. Cables can be passed through roofing membrane laps for connection inside the building (recommended) or connected to adjacent panels in the batten space. Choose to connect panels in rows or columns based on consideration of shading and potential difference.
  • Seite 11 Flashings may have sharp edges, wear gloves. The installation must comply with local regulations on lightning protection. Viridian Solar recommends that the panel installation is carried out by an installer with roofing competence. For best results Don’t rush it.
  • Seite 12 Clearline fusion 60-150 30-60...
  • Seite 13 Clearline fusion Clearline fusion is intended for installation above a continuous, functional underfelt that terminates in a gutter. Interlocking tiles set lower gap ‘X’ 130-150mm. Reduce for thinner tiles, if unsure - contact us Slate. For best results align the bottom edge of panel with the slate line. This may require that slates below the panels are nailed in advance.
  • Seite 14 Clearline fusion t = 25mm t = 22mm B22J t >25mm +SP-5 +SP-5J +5mm +5mm t = 0mm SB16-J SB16-Y SB16-J SB16- *...
  • Seite 15 Clearline fusion TILE BATTENS Roofing kits are provided with brackets suitable for tile battens of 25mm thickness. For 22mm tile battens replace Rafter Brackets (12) with brackets from B22 kit. Replace Combi Rafter Brackets (13) with brackets from B22J kit. For tile battens of greater than 25mm thickness, use the required number of 5mm bracket spacers.
  • Seite 16 Clearline fusion...
  • Seite 17 Clearline fusion The following portrait 3 above 3 installation illustrates how the system works for any rectangular array. Landscape installation follows the same principles OPEN THE YELLOW BOX Start with the bottom left panel. Brackets rotate into the lower slot on the panel frame. Fix the batten brackets (14) to the left side with two 25mm screws (19) each.
  • Seite 18 Clearline fusion...
  • Seite 19 Clearline fusion Fit the sill flashing (2) then the lower side flashing (3) to the panel. Flashings push into the rubber gasket seal in the upper slot of the panel frame. Take care to align the leading edge just above the yellow line on the gasket. If lubrication is required, use glass cleaning fluid. Den Schwellereindeckrahmen (2) und den unteren Seiteneindeckrahmen (3) an das Modul montieren.
  • Seite 20 Clearline fusion...
  • Seite 21 Clearline fusion Secure the edge of the side flashing using side fixing tabs (17) and nail (18). Fold over the tab on the sill flashing (a) to grip the side flashing. Fold down the tab on the side flashing (b). Sichern Sie die Kante des Seiteneindeckrahmens mit den Seitenrahmenbefestigungslaschen (17) und den Nägeln (18).
  • Seite 22 Clearline fusion TY-A TY-A...
  • Seite 23 Clearline fusion OPEN THE GREEN BOX Fix combi rafter brackets (13) to each rafter the panel crosses with four 50mm screws (20) each. ÖFFNEN SIE DIE GRÜNE BOX Befestigen Sie die Kombi-Dachsparrenhalter (13) an jedem Sparren, den das Modul kreuzt, mit jeweils vier 50-mm-Schrauben (20).
  • Seite 24 Clearline fusion...
  • Seite 25 Clearline fusion Push the joining strip (6) into the gasket on the top face of the lower solar panel. Align to the centre of the panel. Slide the upper solar panel down the roof to simultaneously engage with the combi-bracket and the joining strip.
  • Seite 26 Clearline fusion TY-A TY-A...
  • Seite 27 Clearline fusion Fix the left side of the solar panel with batten brackets (14) and 25mm screws (19). Push in the upper side flashing (4) and fix the outside edge with side fixing tabs (17). Fold the protruding end of the joining strip (6) down over the side flashing. Do not fold the protruding end of the joining strip upwards Befestigen Sie die linke Seite des Solarmoduls mit Dachlattenhaltern (14) und 25-mm-Schrauben (19).
  • Seite 28 Clearline fusion...
  • Seite 29 Clearline fusion RED BOX Fix combi-batten brackets (15) to the right hand side of the bottom solar panel. The bracket must be turned so that the side with the taller edge goes into the panel. Fix each brackets with two 25mm screws (19). ROTE BOX Befestigen Sie die Kombi-Dachlattenhalter (15) auf der rechten Seite des unteren Solarmoduls.
  • Seite 30 Clearline fusion 30mm...
  • Seite 31 Clearline fusion Slide the first panel of the next column sideways to engage with the combi-batten brackets. The bracket sets the gap to 30 mm. Secure the new solar panel to each rafter it crosses with rafter brackets (12) and two 50mm screws (20) each. Schieben Sie das erste Solarmodul der nächsten Spalte seitwärts, um es mit den Kombi-Dachsparrenhaltern ineinandergreifen zu lassen.
  • Seite 32 Clearline fusion...
  • Seite 33 Clearline fusion Push the sill flashing (2) into the gasket on the solar panel. Slide the lower gutter (7) between the two solar panels from the top. Fold the tab at the bottom behind the sill flashing. Loop the gutter fixing strip (16) into the slot on top of the gutter.
  • Seite 34 Clearline fusion...
  • Seite 35 Clearline fusion Align the bottom corner of the lower gutter covers (8) with the bottom edge of the solar panel and push the gutter covers into the gasket. Fold down the retaining tabs. Richten Sie die unteren Enden der unteren Ablaufrinnenabdeckungen (8) am unteren Ende des Solarmoduls aus und drücken Sie die Ablaufrinnenabdeckungen in die Dichtung.
  • Seite 36 Clearline fusion...
  • Seite 37 Clearline fusion BLUE BOX Fix combi-rafter brackets (13) to the top of the panel below and combi-batten brackets (15) to the right hand side of the panel to the left. Fit the upper gutter (9) between the solar panels and nail the gutter fixing strip to a batten. Push the upper gutter cover (10) into the panel gasket.
  • Seite 38 Clearline fusion...
  • Seite 39 Clearline fusion For each rafter it crosses, fix a rafter bracket (12) to the top of the top left panel and secure with two 50mm screws (20) each. You may need to add a batten above the panel to support the top flashing.
  • Seite 40 Clearline fusion...
  • Seite 41 Clearline fusion Push the joining strip (6) into the gasket in the top edge of the panel below and slide the solar panel in to engage with the joining strip and combi-brackets on two sides. Fit gutter cover (10) into the panel gasket. Fold the end of the joining strip down into the gutter.
  • Seite 42 Clearline fusion...
  • Seite 43 Clearline fusion ORANGE BOX Fix three combi-batten brackets (15) to the right hand side of the panel to the left. Slide the new panel into position. Fix with rafter brackets (12) on the bottom edge and batten brackets (14) to the right hand side. ORANGE BOX Befestigen Sie drei Kombi-Dachlattenhalter (15) an der rechten Seite des linken Solarmoduls.
  • Seite 44 Clearline fusion...
  • Seite 45 Clearline fusion Push the sill flashing (2) into the gasket at the bottom of the solar panel. Push the lower side flashing (3) into the gasket on the right hand side of the panel. Fit the lower gutter (7), (16) and lower gutter covers (8). See steps 10 and 11. Fit side fixing tabs (17) and fold over the tab on the sill flashing.
  • Seite 46 Clearline fusion...
  • Seite 47 Clearline fusion BLUE BOX Repeat steps 12 to 15 with TC kit and J kit. BLAUE BOX Wiederholen Sie die Schritte 12 bis 15 mit den Bausätzen TC und J. BLAUWE DOOS Herhaal stap 12 - 15 met het TC-pakket en het J-pakket. BLÅ...
  • Seite 48 Clearline fusion TY-B TY-B...
  • Seite 49 Clearline fusion Repeat step 6 to fit batten brackets and upper side flashing Repeat step 14 with TR kit Zur Montage der Dachlattenhalter und des oberen Seiteneindeckrahmens wiederholen Sie Schritt 6. Für den Bausatz TR wiederholen Sie Schritt 14. Herhaal stap 6 voor montage panlatbeugels en bovenste zijgootstuk. Herhaal stap 14 met het TR-pakket.
  • Seite 50 Clearline fusion...
  • Seite 51 Clearline fusion Remove the paper strip on the underside of the sill flashing and dress the lead down onto the tiles. Ensure that the bitumen strip is well-bonded to the tiles. In some circumstances, for example a dusty tile surface, the application of a low modulus external silicone sealant will be required to achieve good adhesion.
  • Seite 52 Clearline fusion Viridian Solar Atlas Building, 68 Stirling Way Papworth, Cambridge. UK CB23 3GY +44 1480 831 501 www.viridiansolar.com viridian s o l a r...

Diese Anleitung auch für:

Solar clearline fusion f16 l