Herunterladen Inhalt Inhalt Diese Seite drucken

Installation; Installation Site - clage DSX Touch Twin Montageanleitung Für Den Fachhandwerker

Unterputzeinbauschrank
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

DSX Touch Twin

4. Installation

www.clage-com.ru
The following regulations must be observed:
• VDE 0100
• EN 806
• Installation must comply with all statutory regulations, as well as those of
the local electricity and water supply companies.
• The rating plate and technical specifications
• Only intact and appropriate tools must be used
• State of the art for the on site installation
• The currently applicable guidelines and regulations for building construc-
tion and design

Installation site

• Appliance must only be installed in frost-free rooms. Never expose appli-
ance to frost.
• In order to avoid thermal losses, the distance between the instantaneous
water heater and the tap connection should be as small as possible.
• For maintenance work, a shut-off valve should be installed in the supply
line. The appliance must be accessible for maintenance work.
• Plastic pipes may only be used if they conform to DIN 16893, Series 2. The
hot water pipes must be thermally insulated.
• For installing in a building wall, it must have a minimum wall thickness of
150 mm.