Herunterladen Diese Seite drucken

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
GB
Thank you for purchasing our digital scale
(MV-100
/MV-1000). With normal care and proper
treatment, this scale will provide years of reliable service.
General Maintenance and Care
1. Avoid exposure to extreme heat or cold. Also avoid any kind of moisture. Always allow your scale
to acclimate to normal room temperature before use.
2. Keep your scale in a clean and dry environment. Dust, dirt, moisture, vibration, air currents and
proximity to other electronic equipment may have an adverse effect on the accuracy and reliability of
the scale.
3. Handle the scale with care. Gently apply all items to be weighed on the tray top. Although this
scale is designed to be quite durable, avoid rough treatment, as this may permanently damage the
internal parts. Always avoid shaking and dropping. This is a precision instrument and should be
handled with extreme care.
Specification and Function
1. Capacity/Accuracy: 100g / 0.01g or 1000g / 0.1g
2. Units: g, oz, ozt, dwt, ct, gn
3. Key function: ON/OFF, TARE, MODE
4. Display: LCD display with backlight
5. Auto off: 180 seconds if inactivity
6. Power: 2 AAA batteries
7. Operation Temp: 10 to 30 deg C
Operation
1. Place the scale on a leveled surface & press "ON/OFF" key to turn on the scale or power it off.
2. Wait until the LCD display shows zero, then press "MODE" key to choose the weighing unit.
3. Place the item to be weighed on the platform and wait until the reading is stable.
Tare Function
1. Turn on the scale as described above.
2. Place the "tare item" on the platform. Press "TARE" key and wait until the LCD displays zero.
3. Scale can now be used for weighing. Add the "net-weight-item".
Calibration
1. When the scale is turned off, press the "ON/OFF" key to turn on the scale. Wait until the LCD
display shows "0.0" or "0.00".
2. Press and hold the "MODE" key until the display shows "CAL", then release the button. Press the
"MODE" key again and the required calibration weight will flash on the display. Place the required
weight onto the center of the platform.
3. The LCD display reads "PASS" and come back to the normal weighing mode. Calibration is now
complete.
Warning
1. "LO": Low voltage. Please replace the batteries.
2. "O-Ld": Overload. Please remove item quickly to protect the scale.
Downloaded from
www.Manualslib.com
manuals search engine

Werbung

loading

Inhaltszusammenfassung für Myco MV-100

  • Seite 1 Thank you for purchasing our digital scale (MV-100 /MV-1000). With normal care and proper treatment, this scale will provide years of reliable service. General Maintenance and Care 1. Avoid exposure to extreme heat or cold. Also avoid any kind of moisture. Always allow your scale to acclimate to normal room temperature before use.
  • Seite 2 Gracias por comprar nuestra balanza digital usted (MV-100 /MV-1000). Con el cuidado normal y el tratamiento adecuado, esta escala le proveerá muchos años de servicio confiable. Mantenimiento General y Atención 1. Evite la exposición al calor o al frío extremo. También evite cualquier tipo de humedad. Siempre permita que su escala se aclimate a la temperatura ambiente normal antes de su uso.
  • Seite 3 Dank u voor de aankoop van onze digitale weegschaal (MV-100 /MV-1000). Met normale zorg en juiste behandeling, zal deze schaal jarenlang een betrouwbare service. Algemeen Onderhoud en verzorging 1. Vermijd blootstelling aan extreme hitte of kou. Ook voorkomen dat elke vorm van vocht. Laat altijd uw weegschaal te wennen aan de normale kamertemperatuur vóór gebruik.
  • Seite 4 Vielen Dank, dass Sie sich für unsere digitalen Skala (MV-100 /MV-1000). Bei normaler Pflege und Behandlung, wird diese Waage über Jahre zuverlässigen Service. Allgemeine Wartung und Pflege 1. Vermeiden Sie extreme Hitze oder Kälte. Vermeiden Sie auch jede Art von Feuchtigkeit. Immer erlauben die Waage, um zum normalen Raumtemperatur vor Gebrauch akklimatisieren.
  • Seite 5 Grazie per aver acquistato il nostro bilancia digitale (MV-100 /MV-1000). Con cura normale e corretto trattamento, questa scala fornirà anni di servizio affidabile. Manutenzione generale e cura 1. Evitare l'esposizione a calore estremo o freddo. Anche evitare qualsiasi tipo di umidità. Lasciare sempre la bilancia raggiunga la normale temperatura ambiente prima dell'uso.
  • Seite 6 Merci d'avoir acheté notre échelle numérique (MV-100 /MV-1000). Avec un entretien normal et un traitement approprié, cette échelle fournira des années de service fiable. Entretien général et des Soins de 1. Eviter l'exposition à la chaleur ou le froid extrême. Evitez également tout type d'humidité.

Diese Anleitung auch für: