Field of application:
The devices are suited only for distributing radio and television signals in the
house! If the device is used for other purposes, no warranty is given!
The illustrations show application examples of the distribution in star (1) or
tree structure (2).
Equipotential bonding and Mounting:
To avoid dangerous overvoltages (attention: risk of fire/death), the devices
must be connected to the equipotential bonding according to EN 60728-11.
 Use the equipotential bonding connection attached to the device (3).
 To connect the outer conductor of the coaxial cable to the equipotential
bonding, use e.g. earth connection blocks CFA or earthing angles QEW at
the input and output of the amplifier.
 Use the mounting screws included in the delivery and the mounting holes
of the devices (4).
4
RF Installation:
 Connect the input of the amplifier to the video interconnection point.
Connect the output of the amplifier to your house distribution.
 Use a highly shielded coaxial cable with an F connector (for TVS 10-00
also IEC connectors possible). Suited cables and plugs can be found in the
current AXING catalogue or at www.axing.com.
3
Adjustments:
 Amplifiers which are equipped with attenuators (5) allow you to adapt the
equalization and attenuation to your installation.
1
2
5
equalization
attenuation