h) NUMERIC BUTTONS: Programmed on RX receivers when required, these transmit a bistable command to the RX receivers by pressing a 1
or 2-digit numeric code followed by red (on) or green (off).
NOTE! The programming of the commands depends on the needs of the customer and subsequent programming performed by the installer: It
is possible to use the buttons for silent telephone calls requesting medical assistance, or in the case of aggression or similar, or to set off alarm
sirens (panic) or to open automatic gates / doors and similar uses. The use of the numeric buttons is recommended for on-off operations such
as switching on lights and/or electric charge control to be manually activated / deactivated. This manual indicates how to access these functions
which, once determined, will remain permanent.
4) SIGNAL OF EVENTS: The keypad signals certain important events by means of the pilot lights relating to the alarm system of which it is a
part, as follows: Light signals are sometimes accompanied by several BEEPS of the buzzer in order to draw attention.
•
ALARM ZONE A,B,C: Indicates the three intrusion alarms zones and lights up when the relative zone is activated.
•
TRANSMISSION : Lights up when keypad HT is transmitting radio signals.
•
WARNING new notice : Lights up at disarming to warn of a new event; check the event memory in the control panel.
•
WARNING door-window open : Lights up upon arming to warn of any protected doors / windows left open.
•
WARNING low battery : Lights up upon arming or disarming to warn that the batteries of the keypad require changing within 7 days.
•
WAIT FOR RECEPTION : Turns on when waiting for command confirmation from control panel.
5) CHECK CONTROL UNIT STATUS : Press the "?" button to interrogate the control unit. When the transmission time and response waiting
time has elapsed, indicated by the relevant red LEDs, the LEDs of the activated zones will light up. If no LED lights up, the system is
deactivated.
6) START-UP – observe operation sequences
a) ASSIGNMENT OF KEYPAD TO CONTROL UNIT
After having switched the keypad on, the buzzer will beep and all LEDs will turn on. The control panel must be (armed and) disarmed within 60
seconds. Upon disarming, the keypad is linked to the control unit; this is confirmed by 6 beeps of the keypad buzzer and by the LEDs turning off.
b) PROGRAMMING / CANCELLATION OF ARMING / DISARMING 5-DIGIT CODES: The operation is performed on the control panel.
c) PANIC AND TAMPER ALARM PROGRAMMING
Set the control panel on the panic or robbery channel according to the kind of alarm required. Keep the panic (!) button pressed for 10 seconds.
The control unit confirms (beep) that the programming has taken place. This program also enables the anti-tamper control which provokes a
tamper alarm if the keypad is opened or removed from the wall. If this program is not performed this protection will not apply.
d) PROGRAMMING OF BUTTONS: F1: prepare the RX receiver to receive the radio transmission, then press the button for 10 seconds (see
also specific instructions of the receiver). F2: prepare the control panel or the RX receiver to receive the radio transmission, then press the
button for 10 seconds. The control panel confirms (beep) that the programming has taken place; for the receivers, see the specific instructions.
e) USE OF KEYPAD HT AS MULTIPLE REMOTE CONTROL
Independently of its application with a Silenya control unit, the keypad can be used as a multiple remote control to activate / deactivate the RX
receivers. This can be done with the " ! " – F2 buttons to transmit an impulse command, or by F1 button or entering one or two digits followed by
red or green button in order to transmit a bistable command (on-off). To program in this way (see 4h), prepare the receiver, enter the numeric
buttons required and press red + green buttons together.
STEUERUNGSTASTATUR FÜR SILENTRON HT Zentralen
ÜBEREINSTIMMUNGSERKLÄRUNG: Hiermit erklärt Silentron S.p.A., dass das in diesem Katalog beschriebene Material mit den
grundlegenden Anforderungen und den anderen diesbezüglichen, durch die EG-Richtlinie 1999/5/CE, EN 50131-1 Grad 1 – Umweltklasse III
und EN 300 220-1 (2006-04) Klasse I festgelegten Vorschriften übereinstimmt.
ALLGEMEINE HINWEISE – VOR INBETRIEBNAHME DER GERÄTE BITTE SORGFÄLTIG LESEN
Installation: Alle Installations- und Wartungsarbeiten, sowie Änderungen am System und seinen Geräten müssen von technisch qualifiziertem
Fachpersonal durchgeführt werden. Diese Geräte können spezifischen technischen Normen unterliegen, die zu beachten sind.
Versorgung durch Batterien: Batterien und/oder Akkus ausschließlich durch gleichwertige Modelle ersetzen, Anbringung und Anschluß unter
Beachtung der in den Anleitungen angegebenen Polung. Leere Batterien gemäß den gültigem Vorschriften entsorgen und diese im Falle der
Verschrottung der Geräte vorher herausnehmen. Bei Austreten von Flüssigkeit, Hände durch Silikonhandschuhe schützen.
Haftung: Der Hersteller lehnt jegliche Verantwortung infolge von unsachgemäßer Installation und/oder Wartung, unsachgemäßer und/oder
nicht erfolgter Benutzung der gelieferten Geräte ab. Gewährleistung: gemaess dem Wienabkommen und den Bedingungen im Katalog –
ausschlie lich Batterien.
1) ALLGEMEINES'
Keypad HT ist eine zweiseitig gerichtete (bistabile) Steuerungstastatur, die die Zentralen der Serie Silenya Top / Free ergänzt und die Gesamt-
/Teilscharfschaltung der Zentrale durch Eingabe eines numerischen Codes von 5 Ziffern mit hoher Sicherheit gestattet. Abgesehen von der
Eingabe des Codes sendet das Gerät auf chiffrierte und nicht für Betrugszwecke reproduzierbare Weise und empfängt von der Zentrale die
Bestätigung der Vorgänge. Darüber hinaus kann die Tastatur einen „Panik"-Alarm und andere Befehle per Funk zur Zentrale oder zu
entsprechenden RX-Empfängern senden, um Hausautomation verschiedener Art zu ermöglichen. Ein interner Buzzer bestätigt die
Codeeingabe und gibt beim Eintreten neuer Ereignisse, oder wenn die Batterien auszuwechseln sind, Tonsignale von geringer Stärke aus.
2) TECHNISCHE DATEN
Stromversorgung: 3 Batterien AA je 1,5V - Stromaufnahme 5 uA in Ruhestellung, 70mA bei Betrieb - Funktionszeit ca. 2 Jahre bei 4
Betätigungen am Tag - lokale Signalisierung leerer Batterie durch wiederholte Pieptöne bei jeder Betätigung.
Funktionen: Steuerung der Zentrale – Alarm-Panik-Sendung - Steuerung RX-Empfänger
Anzeigen und Kontrollen: 8 LED zur Funktionskontrolle (siehe Zeichnung)
Funkübertragung: Codiert mit 40 Bit – Frequenz und Leistung laut Gesetz - Reichweite 100m im Freien, ca. 40m in Innenräumen, falls keine
Störungen auf den Frequenzbändern oder starke Hintergrundgeräusche vorhanden sind.
SILENTRON -
Made In
Italy
COPYRIGHT SILENTRON DF5528XA080319GM
5