Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance; Troubleshooting - AirApp KK26D10060V Bedienungsanleitung

Kompakter universalkompressor mit direktantrieb
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

V.
INITIAL START-Up
1. Open the air receiver's drain valve or outlet valve.
2. Plug power supply cord into correct power source.
3. Run the compressor for a minimum of twenty (20) minutes in this no-load condition to lubricate the bearings and pistons.
4. Close air receiver drain valve and outlet valve. Your compressor is ready for use.
VI.

MAINTENANCE

Before doing any maintenance or adjustments to your air compressor, the following safety precautions should be taken:
*DISCONNECT ELECTRICAL pOWER.
*DRAIN AIR RECEIVER OF pRESSURE.
pARTS LIST
For assistance in solving the parts problem, we have listed all the parts and components for our air compressors by number.
When replacements are needed, include the model numbers of the compressors, part numbers and required quantity.
If a new assembly is required, include the model of the air compressor undergoing repair(see name place), the part name, part
number, and quantity required, according to the numbers on the parts diagram.
1.
DAILY OR BEFORE EACH USE:
* Check oil level.
*Drain condensation from air receiver.
*Check for any unusual noise or vibration.
*Be sure all nuts and bolts are tight.
2.
WEEKLY:
*Clean air filter by opening air filter, removing filter element and cleaning it thoroughly with soapy water.
*Rinse thoroughly and allow to dry completely before assembly.
*Worn filters should be replaced.
3.
MONTHLY:
*Inspect air system for leaks, by applying soapy water to all joints.
*Tighten those joints if leaks are observed.
4.
QUARTERLY OR 300 HOURS (whichever comes first):
*Change compressor oil
*Replace more often if used near paint spraying operations or in dusty, environment.
ATTENTION:
DURING THE BREAK-IN PERIOD, NUTS & BOLTS MAY LOOSEN UP. PLEASE CHECK.
AFTER TWO WEEKS, TIGHTEN ALL NUTS AND BOLTS, INCLUDING HEAD BOLTS, THEN CHECK EVERYTHING ONCE A
MONTH TO MAKE SURE ALL NUTS & BOLTS STAY TIGHT.
Trouble Shooting
pROBLEM
Will not start
Low pressure
© Copyright - AirApp Power Tools GmbH • Siemensstr. 9 - 11 • 40885 Ratingen
Check List
* SpECIAL NOTICE !!
pOSSIBLE CAUSE
Fuse blown or circuit breaker tripped
Loose electrical connections.
Overheated motor.
Air leak in safety valve
Loose tube or fittings
Restricted air filter
Defective check-valve
CORRECTIVE ACTION
Check for cause of blown fuse or brea-
ker and replace or reset.
Check wiring connections.
Press reset button, or wait for automatic
reset.
Check valve manually If Condition per-
sists, replace valve.
Tighten fittings.
Clean or replace as necessary.
Replace check-valve.
9

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis