Resistance measurement
1. Connect the red test wire to the VΩ terminal.
2. Connect the black test lead to the COM terminal.
3. Disconnect the measured circuit from power and discharge
all capacitors.
4. Connect the test leads to the measured circuit.
5. The result will appear on the display.
Temperature measurement
1. Set the rotary switch to °C or °F position.
2. Connect the thermocouple to the socket (pay attention to
correct polarity).
3. The temperature will be displayed.
Insulation resistance measurement
1. Set the rotary switch to 2000 MΩ position. Unstable
reading is normal.
2. Connect the tester (optional, not in set) to connection
terminals.
3. Set the rotary switch to 2000 MΩ position.
4. Connect the test leads to measured circuit.
5. Turn on the tester.

CLEANING AND MAINTENANCE

• Clean the device with soft, slightly damp cloth, without
abrasive agents.
• To change the battery, unscrew the screw of the battery
compartment. Take out the battery compartment cover and
replace the battery (note the polarity). Close the battery
compartment cover and screw in the screw.