CIRCULATION PUMPS TYPE EVO+
NOTE
Please consider type plates of other components
if necessary!
4.3 SET-UP OF THE PRODUCT
Pumps with glue fitting
For a sucessfull glued connection it is necessary to be
aware of the functions of glued connections. The most
common reason for a weak/failed glued connection is
not the glue strength, but the insufficient preparation
of the surfaces which shall be glued or the wrong
selection of glue for this application.
Greasing of the surface to be glued
One requirement for a successful glued connec-
tion is to completely remove all remaining oil,
grease, dust and other dirt from the surfaces to
be glued. All dissolvers entirely evaporating of
the cleaned glue surface are suitable. (e.g.
„Henkel" tangit cleaner for PVC and ABS).
Glueing of the parts
For glueing of PVC and ABS parts, a special glue
shall be used (e.g. „Henkel" tangit glue or „Würth"
FSK glue). For the right usage and amount of
glue, please see the specific manual of the glue
product and safety notes of the manufacturer.
Final strength after 24 hours.
Pumps with screw fitting
For pumps with screw fitting only the usage of teflon
tape for sealing the connection is recommended as other
sealing materials could cause damages on the windings.
4.4 DETAILS ABOUT INSTALLATION LOCATION
4.4.1 REQUIRED SPACE FOR OPERATION AND
MAINTENANCE
The pump aggregate needs to installed that an
exchange of parts or the complete unit is possible.
With heavy aggregates, there needs to be space for
other possibilities according to the weight for the safe
use of hoisting devices and other additives. There
have to be driveways for haulage and evacuation.
4.4.2 ACCEPTABLE ENVIRONMENTAL INFLUENCES
It is very important, that the pump and the aggregates
will be installed in a dry, frost-proof and vibration-free
area. The temperature should not be lower than +4°C
and not more than +40°C. Aberrations possible on
request. In general a good venting is necessary.

OPERATION:

The maximum allowed temperature of the medium
to be pumped is +40°C.
4.4.3 SUPPLY CONNECTIONS
Draining of the pump
The plug for draining the pump is situated in the pump
case. In case of producing water hazarding liquids, it has
to be made sure not to end up in the sewage system!
10
WWW.NORSUP.EU
DANGER
DANGER TO HEALTH BY
ROTATING PARTS
The drainage and venting of the
pump must take place at cessation.
DANGER
DANGER TO HEALTH BY LEAKING
MEDIA
The installation of the machine and
machine parts has to be operated
by technically qualified personnel
according to the prevailing safety
regulations in the manual.
Personal protective equipment
needs to be used.
4.4.4 UNDERGROUND, GROUNDING, WALL
The grounding needs to be relevant to make sure the
whole pump can be installed safe and strainless.
Strains could lead to an early wearing of the pump
and/or its components or the motor. Please take care,
that no external vibrations will come through the
underground into the pump. Installation work needs
to follow the rules for reducing the body and air sound
transmission. It is recommended to use damping or
absorbing materials for the installation.
see 5.3 Guidance before set-up, installation and
assembly and 5.4 Pipework
4.5 EMISSION VALUATION
In case the sound intensity level of the product,
operating point, motor, pipeline, type ... is above 85 dB.
CAUTION
DANGER OF SOUND EMISSION
Ear protection necessary
(personal safety equipment)
4.6 DIMENSIONS AND WEIGHT
You will find the dimensions and the weight of the
delivered product on the dimensional drawing in the
technical documentation.
Alterations which serve the technological progress as well as errors excepted!
CIRCULATION PUMPS TYPE EVO+
5.
INSTALLATION AND ASSEMBLY MANUAL
5.1
SAFETY NOTES
NOTE
The installation of the machine and machine
parts has to be operated by technically qualified
personnel according to the prevailing safety
regulations in the manual.
5.2
INSPECTION BEFORE SET-UP, INSTALLATION
AND ASSEMBLY
Before beginning with the installation, immediately
after delivery please confirm the serial number and
pump type on the product compares with the
delivery slip. Possibly delivered equipment needs to
be checked for completeness. Visually check the
delivered product(s) for any damages.
In case of a transport damage, please directly contact
the manufacturer or authorized partner.
CAUTION
Take care that no packing
material is left in or on the
product.
see 3.2.2 Unpacking
5.3
GUIDANCE FOR SET-UP, INSTALLATION
AND ASSEMBLY
NOTE
The installation of the machine and machine
parts has to be operated by technically qualified
personnel according to the prevailing and in the
manual stated safety regulations.
5.4 PIPEWORK
CAUTION
Pump needs to be mounted
horizontally
The suction line should be as
short as possible to reduce
pressure losses which could
lead to performance loss and
bad suction behaviour
Install pipes stressfree
Fill the suction line and pump
with the medium before usage
The pumps can be mounted above or below water
level. For heights see the following table.
Alterations which serve the technological progress as well as errors excepted!
CAUTION
Pipework and water supply
need to be designed according
valid rules to avoid any chance
that the pump will suck air.
Dry running of the pump causes high damages on the
pump and seals.
Pressure line
Between discharge side of the pump and the pressure
line there needs to be a shut-off slide and a non-return
valve. Additionally you can use the slide to adjust the
flow rate and height while the non-return valve avoids
line shocks when shutting-down the pump.
The installed pump will be pressure tested at the
manufacturer.
CAUTION
Pipelines should be pressure
tested without pump, otherwise
the pump could be damaged.
5.5
INSTALLATION AND ASSEMBLY RULES FOR
EMISSION REDUCTION
During installation please check each threadened
connection.
CAUTION
DANGER BY VIBRATIONS AND
SOUND LEVEL
AIt must be checked that the
screws and connections are tight.
Observe valid bolting torques!
Inobservance could lead to higher vibrations and a
higher noise level, which could cause physical and
mental damages.
5.6 SAFETY EQUIPMENT
5.6.1 MECHANICAL
The installed safety equipment mustn't normally be
removed. Demounting is only allowed during halt of
the product in case of necessary maintenance.
CAUTION
DANGER OF CAPTURE BY ACCI-
DENTAL START-UP OF THE SHAFT
Disconnect power source!
see 5.7 Power supply
connection
After work is finished, all removed safety equipment
needs to be mounted again before start-up.