Herunterladen Inhalt Inhalt Diese Seite drucken

Fatar Studio 900 Anleitung Seite 12

Midi-keyboard-controller
Vorschau ausblenden Andere Handbücher für Studio 900:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

CONTROLLER NUMBER
CONTROLLER FUNCTION
0
Bank
1
Modulation
2
Breath controller
3
Undefined
4
Foot controller
5
Portamento rate
6
Data Entry MSB
7
Volume
8
Balance
9
Undefined
10
Pan
11
Expression
12- 15
Undefined
16
Gen'l Purpose #l
17
Gen'l Purpose #2
18
Gen'l Purpose #3
19
Gen'l Purpose #4
20- 31
Undefined
32
Bank
33- 63
Least significant byte for valuesO to 31
64
Sustain (damper)
65
Portamento On/ Off
66
Sostenuto
67
Soft Pedal
68
Undefined
69
Hold 2
70 - 7
Undefined
80
Gen'l Purpose #l
81
Gen'l Purpose #2
82
Gen'l Purpose #3
83
Gen'l Purpose #4
84 - 91
Undefined
92
Tremolo Depth
93
Chorus Depth
94
Detune
95
Phaser Depth
96
Data increment
97
Data decrement
98 - 121
Undefined
122
Local control On/Off
123
All Notes Off
124
Omni Off
125
Omni On
126
Mono On - Poly Off
127
Poly On - Mono Off
Refer to a MIDI technical handbook for further information on these controller
functions.
22
STUDIO 900
Transposition:
Sometimes a player may not be able to play in a certain key. At these times the
[TRANSPOSE] switch will be invaluable. For example, if you need to change from
the key of C major to the key of Eb major, you can still play the C major keys, but
what you hear would be Eb major.
To transpose the keyboard, hold the [TRANSPOSE] switch and press the desired key on the
keyboard above or below middle C. The result will be a new key change when the C major
keys are played. Your range is limited to 24 half steps up and 24 half steps down.
If there are any technical problems that relate to the ST-900 only, please contact Music
Industries Corp. 800-431-6699. Best of luck!!!
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment on and off, the
user is encouraged to try to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving antennas.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
recelver
is connected.
• Consult the dealer or an experienced radio/TV technician for help.
NOTE: Use of shielded power and interface cables with this equipment is required in order
to ensure compliance with FCC specifications.
CAUTION: Changes or modifications to this equipment not expressly approved by the
manufacturer responsible for compliance could void the user's authority to operate the
equipment.
Figure #3
It is recommended that only FCC class B certified devices be used with this equipment.
Operation of Class A equipment in a residential area is likely to cause harmful interference
in which case the user will be required to correct the interference at his or her own
expense.
23
STUDIO 900

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für Fatar Studio 900

Diese Anleitung auch für:

Studio 90plus

Inhaltsverzeichnis