Item-No. 57 75 89
Intended Use
The light is intended for use outdoors (protection type IP68) and it may also be used under water (e.g. to
illuminate a pond, swimming pool or suchlike).
Any other use than that described above may damage the product. Moreover, this may give rise to hazards
such as short-circuiting, fire, electric shock, etc. No part of the product may be modified or converted!
The safety instructions must be observed at all times!
This product complies with the applicable National and European requirements.
All names of companies and products are the trademarks of the respective owner. All rights reserved.
Package Contents
• Light
• Stand
• Ground spike
• Operating Instructions
Explanation of Symbols, Inscriptions
This symbol indicates a health hazard, e.g. electric shock.
The exclamation mark indicates particular risks in handling, function and use.
IP68
Protection Type IP68, product suitable for operation in or under water (max. depth 5 m)
The product complies with protection class III.
Safety Instructions
Read the complete operating manual carefully before using the product as it contains
important information about the correct installation and operation.
The warranty will be void in the event of damage caused by failure to observe these safety
instructions! We do not assume any liability for any consequential damage!
Nor do we assume any liability for material and personal damage caused by improper use
or non-compliance with the safety instructions! The warranty will be void in such cases!
• The unauthorised conversion and/or modification of the product is not allowed for safety and
approval reasons.
• The product is not a toy and should be kept out of the reach of children!
• The product must only be operated using a suitable transformer with an output voltage of
12 V/AC. Never try to operate the product at another voltage as this will cause its destruction.
• The device is designed according to protection class III.
• The product is protected according to IP68. It is intended for use outdoors, where it can also
be operated in or under water.
• The product must not be exposed to extreme temperatures, strong vibrations or heavy
mechanical stress.
• Do not use this product in rooms or under adverse ambient conditions where combustible
gases, vapours or dust are or may be present! There is a risk of explosion!
• The product may only be used when it is installed in a stationary location.
• Attention, LED light:
Do not look directly into the LED light!
Do not look into the beam directly or with optical instruments!
• Do not leave packing materials unattended. They may become dangerous playthings for
children.
• On industrial sites, the accident prevention regulations of the association of the industrial
workers' society for electrical equipment and utilities must be followed!
• If you have reason to assume that safe operation is no longer possible, disconnect the product
immediately and secure it against inadvertent operation. Let an expert check the product.
It can be assumed that safe operation is no longer possible if:
- the product shows visible signs of damage,
- the product does not work at all or well (flickering light, leaking smoke or a smell of burning, the
light flickers, audible cracking noises, discolouration to the product or the adjacent surfaces.)
- the device was stored under unfavourable conditions for a long period of time or
- the device was exposed to serious stress during transport.
Preparations for Installation
www.conrad.com
• The product is suitable for use in unprotected areas outdoors; it may also be operated in or under water
(protection type IP68).
Version 07/16
The maximum water depth for operating the light is 5 m.
°
• The product is only intended for use in freshwater. Protect the light from salt water (e.g. de-icing salt in the
winter) since this may cause corrosion.
• Only install the light on a stable surface.
• Place the connecting cable so nobody can trip over it. The connecting cable must not be driven over by
vehicles; moreover, do not step on the cable!
This can damage the connecting cable (short-circuit or break), which will not only destroy the light, but
possibly the transformer that is used for operation as well.
• The light and the connecting cable are only intended for use in stationary locations.
• The transformer used to power the light must be protected on the distribution board, provided by the user,
by a 10/16A fuse. Please consult the operating instructions for the transformer.
• During installation and connection of the light, the power must be disconnected. Switch off the transformer used
to supply the power, or unplug its mains plug from the mains socket.
Installation/Connection
• The delivery includes a round stand as well as a ground spike.
Depending on where and how you wish to place the light, the appropriate support has to be bolted to the
bottom of the light.
The tilt of the light can also be adjusted via the screw fastening.
• Connect the connecting cable of the lamp with your transformer (output voltage 12V AC). For the data for
the light, please see the chapter "Technical Data".
The polarity is not important for the connection.
• Place the light in the desired installation location and adjust the light beam accordingly. For this purpose,
loosen the screw fastening on the stand, rotate the light into the appropriate position and retighten the screw
fastening.
Maintenance and Care
The light does not require maintenance. Never dismantle the product.
Prior to cleaning, the light must be switched off; allow it to cool down sufficiently.
The outside of the light should only be cleaned with a soft, clean cloth. Where it becomes very dirty, use a cloth
which is slightly moistened with lukewarm water.
Never use aggressive cleaning agents or chemical solutions as the surface of the housing could be damaged
(discoloured).
Disposal
Technical Data
Operating voltage ..........................................12 V/AC
Input...............................................................Max. 2.5 W
Protection class .............................................III
Protection type ...............................................IP68
Bulbs ..............................................................1x LED (1 W), not replaceable
Colour temperature ........................................3000-3200 K (warm white)
Luminous flux ................................................85 lm
Cable length ..................................................approx. 4.5 m
Water depth for operation of the light ............Max. 5 m
Dimensions ....................................................30 x 73 mm (Ø x L), light without support/stand
Weight ...........................................................Approx. 460 g (with connecting cable, without support/stand)
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in
electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
This publication represent the technical status at the time of printing.
Copyright 2016 by Conrad Electronic SE.
The length of the connecting cable is approx. 4.5 m. In order to benefit from the maximum water
depth, or to lay the cable over long distances underwater, the connecting plug requires the
appropriate type of protection.
The light's connecting plug as well as the actual socket on the transformer, or the terminal block,
required for operation are not waterproofed for use in or under water! Protect them from water
intrusion, e.g. with a suitable housing or similar.
Read the information in chapter "Preparations for Installation" prior to installation and connection!
Please dispose of the device when it is no longer of use, according to the current statutory
requirements.