EN – Operating Manual
Due to changes in the product, the procedures stated
can change. This can take place without prior notice
or adaptation of the operating manual and is no cause
for complaint, return or price reduction. The user is
responsible for recognizing discrepancies between
the operating manual and the actual handling of the
breathalyzer and must react accordingly.
ONLY USE ORIGINAL ACE INSTRUMENTS
MOUTHPIECES
Guarantees test result accuracy
Guarantees hygiene of you and the device
Guarantees full warranty of this device
ACE INSTRUMENTS ADVISES
even if you get a result meaning „safe range", you
should never drive after consuming alcohol or do any
other activities that are severely impaired by alcohol
consumption and might endanger your health and safety
or the health and safety of others.
DISPLAY INDICATIONS
DISPLAY
MEANING
H
This letter means that
the device detected an
out of range high alcohol
concentration (= above
4.00‰ (g/L) / 0.40% BAC
/ 2.00mgL).
FLo
The sampling volume
was not enough or the
blow power was too
uneven to analyze the
breath sample.
ACTION
No action
required.
Please perform
a new test.
Press the start
button, the
countdown will
start again. Start
breathing as
soon as "rdY"
appears on the
display.
25
Snr
This means that the
sensor is not ready
for a breath sample.
This happens if high
concentration of alcohol
residue or pollutant is
found on the sensor after
the last test.
rPt
The device could
not complete the test
successfully.
Out
The testing cannot be
performed because
the device is turned on
outside of the operating
temperature.
Lo
The testing cannot be
performed because the
battery is low.
CALIBRATION
To maintain the accuracy of the breathalyzer, ACE
Instruments recommends a calibration after 300 tests
or approx. every 12 months (depending which incident
happens first). For a calibration service you can send
the device to ACE Instruments (see www.alkomat.net).
The calibration is not mandatory, but the accuracy of the
breathalyzer will decrease steadily without it and additionally
the warranty for the sensor expires.
We recommend sending it as a parcel, so that in case of
loss an inquiry or proof of delivery is possible.
Switch off the
device and
wait at least
5 minutes
before starting
it again.
Please press
the Power
button and
perform a new
test.
Repeat the test
after the unit
has reached
a temperature
within the
operation range
(10°C up to
40°C).
Replace the
batteries with
2 new AA
Alkaline
batteries.
26