Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

®
OBID
classic-pro
4.2

Connection

The reader has to supplied by a limited power supply (e.g. NEC Class 2/LPS power supply) ac-
cording IEC EN 60950, only.
Colour
red
black
green
white
violet
grey
brown
yellow
blue
pink
red / blue
grey / pink
*) If the power is not supplied via the controller the power supply GND must be connected
to the controller GND.
**) The digital inputs may only be wired to ground. Wiring to an external power supply may
destroy the input.
Controller
Data / Data0
Clock / Data1
LED green
LED red
FEIG ELECTRONIC GmbH
Function
Vcc (+9 to 15 V DC)
GND*
Data / Data0
Clock / Data1
CLS / Card Present
LED green
LED rot
Beeper
Hold
RS232-TTL (Rx)
RS232-TTL (Tx)
- N.C. -
+9..15 V DC
Vcc
CLS
Beeper
Hold
GND
RS232 TxD
RS232 RxD
Installation
Description
Power Supply
Clock/Data interface
(magnetic strip/ Wiegand)
digital input**
Service and Data Output
Interface
max. 150 m
RS232
RS232-TTL
Page 21 of 24
ID CPR.03.20-CD
red
green
white
violet
grey
brown
yellow
blue
black
pink
red/blue
max. 3 m
M60100-3de-ID-B.doc

Werbung

Kapitel

Inhaltsverzeichnis
loading