The printing of the type designation on the connec-
tion cable is mandatory.
For single-phase AC motors, we recommend a fuse
rating of 16A (C) or 16A (K) for machines with a high
starting current (starting from 3000 watts)!
AC motor 230 V/ 50 Hz
Mains voltage 230 Volt / 50 Hz.
The mains connection and the extension cable have
to­lbe­lthree-core­lcables­l=­lP­l+­lN­l+­lSL.­l-­l(1/N/PE).
Extension cables must have a minimum cross-section
of 1.5 mm². Mains fuse protection is 16 A maximum.
Three-phase motor 400 V / 50 Hz
Mains voltage 400 V / 50 Hz
Mains voltage and extension cables must be 5-lead
(3P­l+­lN­l+­lSL­l(3/N/PE).
Extension cables must have a minimum cross-section
of 1.5 mm².
Mains fuse protection is 16 A maximum.
When connecting to the mains or relocating the ma-
chine, check the direction of rotation (swap polarity in
the wall socket if necessary). Turn pole inverter in the
machine socket.

11. Cleaning

Attention!
Pull out the power plug before carrying out any clean-
ing work on the equipment.
We recommend that you clean the equipment imme-
diately after you use it.
Clean the equipment regularly with a damp cloth and
some soft soap. Do not use cleaning agents or sol-
vents; these may be aggressive to the plastic parts in
the equipment. Ensure that no water can get into the
interior of the equipment.

12. Transport

For transport, the splitting knife A must be completely
moved down. Slightly tilt the log splitter with handle B
on the splitting column until the machine is inclined on
the wheels and can be moved. (Fig 12)

13. Storage

Store the device and its accessories in a dark, dry
and frost-proof place that is inaccessible to children.
The optimum storage temperature is between 5 and
30˚C.­l
Cover the electrical tool in order to protect it from
dust and moisture. Store the operating manual with
the electrical tool.
 www.scheppach.com /  service@scheppach.com /  +(49)-08223-4002-99 /  +(49)-08223-4002-58

14. Maintenance

Attention!
Pull out the power plug before carrying out any main-
tenance work on the equipment.
When must the oil be changed?
First oil change after 50 operating hours, then every
250 operating hours.
Oil change
• Completely retract the splitting column.
• Put a container with a volume of at least 6 litres
under the splitter.
• Release the oil dipstick (8).
• Open the oil drain plug under the oil tank so the oil
can­lfow­lout.­l
• Afterwards, close the oil drain plug again.
• Remove the ventilation cap, pour in 4 litres of fresh
hydraulic oil using a clean funnel.
• Screw the oil dipstick in again.
Dispose of the used oil in a correct manner at a
public collection facility. It is prohibited to drop
old oil on the ground or to mix it with waste.
We recommend oil from the HLP 32 range.
Splitting spar
Before use, the spar of the splitter must be slightly
greased.­l Repeat­l this­l procedure­l every­l five­l operating­l
hours. Slightly apply grease of oil spray. The spar
may never run dry.
Hydraulic system
The hydraulic unit is a closed system with oil tank, oil
pump and control valve.
The system is complete when the machine is deliv-
ered, and may not be changed or manipulated.
Connections and repairs
Connections and repairs of electrical equipment may
only be carried out by an electrician.
Please provide the following information in the event
of any enquiries:
• Type of current for the motor
• Machine data - type plate
• Machine data - type plate
Service information
Please note that the following parts of this product
are subject to normal or natural wear and that the fol-
lowing parts are therefore also required for use as
consumables.
Wear parts*:
splitting wedge guides, hydraulic oil, split-
ting wedge
* Not necessarily included in the scope of delivery!
GB | 23