Herunterladen Diese Seite drucken

ASTEC LPS250 Serie Installation

Schaltnetzteil
Verfügbare Sprachen

Verfügbare Sprachen

Installation Notes
LPS250 Series
Input Specifications
Input range
Frequency
Inrush current
Efficiency
Power factor
EMI filter
Electromagnetic
compatibility
Safety ground
leakage current
Environmental
Operating temperature: 0°C to 50°C ambient;
derate at 2.5% / °C from 50°C to 70°C
Storage temperature:-40°C to 85°C
Thermal regulation: ± 0.04% / °C
MTBF:
> 100,000 hours at full load and 25°C
ambient conditions
Notes (refer to table)
1. Peak current lasting < 30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output
n.
voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF
capacitor.
4. Output voltage user adjustable over range shown. Factory set at nominal
voltage.
5. Minimum load required for regulation, Unit will operate at no load but over
voltage protection may latch.
6. Continuous maximum power drawn must not exceed 250W with fan cooling.
Not to be used without cooling fan.
Mating Connectors
SK1 AC Input:
TB1 Main DC O/p: Screw terminals M3.5 spade
SK3 Auxiliary:
SK4, 5, 7 Fan/Aux: Housing Molex 22-01-1022
Crimps: 22/30 AWG Molex 08-50-0032
Notes
1 Specifications subject to change without notice.
2 All dimensions are in mm and (inches).
3 Output Common capacitivily coupled to chassis earth.
4 This power supply must be earthed for safe operation via SK1-3
connector.
5 Unit supplied with cover fitted.
6 Fan cooling required. Recommended position at mains terminal end
blowing into unit. 30CFM forced air required
7 Weight 1.41 kg / 3.1 lb.
Warning: Hazardous mains voltages present within
this unit. Please see enclosed 'Astec Installation and
Operating Instructions'.
250 Watts
85 VAC to 264VAC
120 VDC to 370 VDC
47 - 440 Hz
<38 A peak
75% typical at full load
0.99 typical,
meets EN61000-3-2
Meets FCC Class B
CISPR 22 Class B
(includes EN55022 class B and
VDE 0878 PT3 class B)
Meets IEC801-2 level 3,
IEC801-4 level 3
and IEC801-5 level 3
< 0.5mA @50/60Hz, 264VAC
input
Screw terminals M3.5 spade
Housing Molex 22-01-1082
Single Output
Output Specifications
Maximum
wattage
Adjustment
range
Hold-up time
Overload
protection
Overvoltage
protection
Supervisory
output
Fan supply
output
Safety
VDE
UL
CSA
NEMKO
BABT
CB
(or 22-01-2085)
(or 22-01-2025)
(or 08-50-0114)
250W with 30CFM forced air with cover:
200W with 30CFM forced air, without cover.
2:1 adjustment range
20 ms at 250W load and 115 VAC nominal
line
Short circuit protection. Auto recovery. Total
power limited @ 110% to 145% above peak
rating
10% to 25% above output voltage setting.
Tracks with output voltage. Recycle AC to
reset.
5V / 100mA regulated; output maintained
when main outputs inhibited. (for use with
inhibit and power good function)
12V / 200mA; output maintained
when power supply inhibited.
0805/EN60950 (IEC950)
UL1950
CSA 22-2-234 Level 3
EN 60950/EMKO-TUE (74-sec) 203
EN60950/BS7002
Certificate and report
This product is CE marked following
the provisions of the Low Voltage
Directive 73/23/EEC
Auxiliary Connections
1 Remote sense - optional connection- can
compensate for up to 0.5V drop; internal
local sense connected if not used. Protected
against reverse connection.
2 AC Power Fail signal;-TTL compatible signal
goes high 50-150ms after switch on. Goes
low >4 ms before 5V drops to 4.75V.
3 DC Power OK:- TTL compatible signal goes
high at same time as AC Power Fail. Goes
low when 5V drops to 4.75V.
4 Remote Inhibit. Connecting pin 3 to pin 5
(common) will inhibit the outputs.
5 Remote Enable. To convert to enable, cut
jumper J1; connecting pin 4 to pin 5 will
enable outputs.
6 Paralleling power supplies - when the 'C
share' signal is connected between two
power supplies the main 5V outputs will
current share.
Fusing
Input fuse 6.3A 20mm Quick Acting HBC
mains fuse - only replace with same type
and rating to maintain safety standards.
loading

Inhaltszusammenfassung für ASTEC LPS250 Serie

  • Seite 5 Bedienungs Anleitung LPS250 Serie 250 Watt Einfach Ausgang Eingangs Spezifikationen Ausgangs Spezifikationen Eingangsbereich 85 VAC to 264 VAC Maximale 250W mit Gehäuse und 51m /Std 120 VDC bis 370 VDC Ausgangsleistung (30CFM) Luftkühlung Frequenz 47 - 440 Hz 200W ohne Gehäuse und 51m /Std (30CFM) Luftkühlung...

Diese Anleitung auch für:

Lps252-cLps253-cLps254-cLps255-c