Sentera Controls RSVCX-R Montage- Und Bedienungsanleitung Seite 11

Multifunktionaler raumtransmitter
Vorschau ausblenden Andere Handbücher für RSVCX-R:
Inhaltsverzeichnis
RSVCX-R
HOLDING REGISTERS
1
Device slave address
2
Modbus baud rate
3
Modbus parity mode
4
Device type
5
HW version
6
FW version
7—8
Modbus network
9
resistor termination
(NBT)
Modbus registers
10
reset
Minimum
11
temperature range
Maximum tempera-
12
ture range
Minimum
13
temperature alert
Maximum
14
temperature alert
15—18
Minimum relative
19
humidity range
Maximum relative
20
humidity range
Minimum relative
21
humidity alert
Maximum relative
22
humidity alert
Minimum CO
eq
23
2
range
Maximum CO
eq
24
2
range
25
Minimum CO
eq alert
2
26
Maximum CO
eq alert
2
27
Minimum TVOC range
Maximum TVOC
28
range
29
Minimum TVOC alert
30
Maximum TVOC alert
31—34
35
Active level
36
Standby level
37—40
41
Output 1 type
Output 1 overwrite
42
enable/disable
Output 1 overwrite
43
value
Output 1 internal
44
voltage source
selection
45
Output 1 min value
MIW-RSVCX-R-DE-000 - 22 / 07 / 19
MULTIFUNKTIONALER
RAUMTRANSMITTER
Data type
Description
unsigned int.
Modbus device address
unsigned int.
Modbus communication baud rate
unsigned int.
Parity check mode
unsigned int.
Device type (Read only)
unsigned int.
Hardware version of the device (Read only)
unsigned int.
Firmware version of the device (Read only)
Reserved, return 0.
Set device as ending the line or not by
unsigned int.
connecting NBT
Resets Modbus Holding registers to default
unsigned int.
values. When finished this register is
automatically reset to '0'
Minimum value of temperature range, cannot
signed int.
be set higher than maximum temperature range
minus 5°C
Maximum value of temperature range, cannot
signed int.
be set less than minimum temperature range
plus 5°C
signed int.
Minimum temperature alarm value
signed int.
Maximum temperature alarm value
Reserved, return 0.
Minimum value of relative humidi-ty range,
unsigned int.
cannot be set higher than maximum relative
humidity range minus 5%
Maximum value of relative humid-ity range,
unsigned int.
cannot be set less than minimum relative
humidity range plus 5%
unsigned int.
Minimum relative humidity alarm value
unsigned int.
Maximum relative humidity alarm value
Minimum CO
eq range, cannot be set higher
unsigned int.
2
than maximum CO
eq range minus 100 ppm
2
Maximum CO
eq range, cannot be set less than
unsigned int.
2
minimum CO2eq range plus 100 ppm
unsigned int.
Minimum CO
eq
alarm value
2
q
unsigned int.
Maximum CO
eq alarm value
2
Minimum TVOC range, cannot be set higher
unsigned int.
than maximum TVOC range minus 100 ppb
Maximum TVOC range, cannot be set less than
unsigned int.
minimum TVOC range plus 100 ppb
unsigned int.
Minimum TVOC alarm value
unsigned int.
Maximum TVOC alarm value
Reserved, return 0.
The ambient light level above which 'Active' is
indicated in input register 6
The ambient light level below which 'Standby' is
indicated in input register 6
Reserved, return 0.
unsigned int.
Select analogue / modulating output 1 type
unsigned int.
Enables the direct control over output 1
Overwrite value for output 1. Active only if
unsigned int.
Holding register 42 is set to 1
unsigned int.
Select internal voltage source for PWM output 1
Set minimum value of output 1 signal in
unsigned int.
percentage
zurück zum Inhaltsverzeichnis
Data
1—247
0—6
0—2
RSVCX-R = 1126
XXXX
XXXX
0—1
0—1
-300 – (Max. range
- 50)
(Min. range + 50)
– 700
Min. temperature
range – Max.
temperature alarm
Min. temperature
alarm – Max. tem-
perature range
0 – (Max. range
- 50)
(Min. range + 50)
– 1000
Min. relative
humidity range
– Max. relative
humidity alarm
Min. relative
humidity alarm
– Max. relative
humidity range
400 – (Max. range
- 100)
(Min. range + 100)
– 60000
Min. CO
2
Max. CO
Min. CO
2
Max. CO
0 – (Max. range
- 100)
(Min. range + 100)
– 60.000
Min. TVOC range –
Max. TVOC alarm
Min. TVOC alarm –
Max. TVOC range
0—32000
0—32000
1—3
0—1
0—1
0—40
www.sentera.eu
Default
Values
1
0 =
1 =
2 =
2
3 =
4 =
5 =
6 =
0 =
1
1 =
2 =
0x0100 =
0x0100 =
0 =
0
1 =
0 =
0
1 =
0
100 =
500
700 =
0
100 =
500
700 =
0
200 =
1000
1000 =
0
200 =
1000
1000 =
400
400 =
2000
2000 =
eq range –
400
400 =
eq
2
eq alarm –
2000
2000 =
eq range
2
0
1000=
2000
2000 =
0
100 =
2000
2000 =
100
100 =
100
10 =
1 =
1
2 =
3 =
0 =
0
1 =
0 =
0
1 =
0
20 =
4.800
9.600
19.200
38.400
57.600
115.200
230.400
8N1
8E1
8O1
HW version 1.00
FW version 1.00
NBT disconnected
NBT connected
Idle
Reset Modbus
Registers
10,0°C
70,0°C
10,0°C
70,0°C
20,0 % rH
100 % rH
20,0 % rH
100 % rH
400 ppm
2000 ppm
400 ppm
2000 ppm
1000 ppb
2000 ppb
100 ppb
2000 ppb
100 lux
10 lux
1—10 VDC
0—20 mA
PWM
Disabled
Enabled
3,3 VDC
12 VDC
20%
11 - 12