MHL510 LED Beam Bar 5x10W Quad
Ref. nr.: 150.516
INSTRUCTION MANUAL
GEBRUIKSAANWIJZING
GEBRAUCHSANLEITUNG
MANUAL DE INSTRUCCIONES
V1.1

Werbung

Inhaltsverzeichnis
loading

Inhaltszusammenfassung für Beamz professional MHL510

  • Seite 1 MHL510 LED Beam Bar 5x10W Quad Ref. nr.: 150.516 INSTRUCTION MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANLEITUNG MANUAL DE INSTRUCCIONES V1.1...
  • Seite 2 ENGLISH Congratulations to the purchase of this Beamz light effect. Please read this manual thoroughly prior to using the unit in order to benefit fully from all features. Read the manual prior to using the unit. Follow the instructions in order not to invalidate the warranty. Take all precautions to avoid fire and/or electrical shock.
  • Seite 3 NEDERLANDS Hartelijk dank voor de aanschaf van dit Beamz lichteffect. Neemt U a.u.b. een paar momenten de tijd om deze handleiding zorgvuldig te lezen, aangezien wij graag willen dat u onze producten snel en volledig gebruikt. Lees deze handleiding eerst door alvorens het product te gebruiken. Volg de instructies op anders zou de garantie wel eens kunnen vervallen.
  • Seite 4 DEUTSCH Vielen Dank für den Kauf dieses Beamz gerat. Nehmen Sie sich einen Augenblick Zeit, um diese Anleitung sorgfältig durchzulesen, damit sie die Möglichkeiten, die unser Produkt bietet, sofort voll ausnutzen können. Lesen Sie erst die Anleitung vollständig vor der ersten Inbetriebnahme durch. Befolgen Sie die Anweisung, da sonst jeglicher Garantieanspruch verfällt. Treffen Sie stets alle Sicherheits-vorkehrungen um Feuer und/oder Stromschlag zu vermeiden.
  • Seite 5 ESPAÑOL Enhorabuena por la compra de este efecto de luces Beamz. Por favor lea atentamente este manual antes de usar el aparato para disfrutar al completo de sus prestaciones. Seguir las instrucciones le permite no invalidar la garantía. Tome todas las precauciones para evitar que se produzca fuego o una descarga eléctrica.
  • Seite 6: Installation

    INSTALLATION CAUTION: Please consider the respective national norms during the installation! The installation must only be carried out by an authorized employee or dealers! Attention:  The installation of the fixture has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harming deformation.
  • Seite 7 FIXTURE CLEANING The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s optics. ...
  • Seite 8: Control Menu

    CONTROL MENU Operation Display Description MENU1: Dmx512 UP/DOWN to choose 1-512, press ENTER to save Dmx512 17CH: xxx PRESS Dmx512 UP/DOWN to choose 1-512, press ENTER to save ENTER 12CH: xxx Tilt MENU2: Y clockwise, press ENTER to save Tilt PRESS Tilt Y anti-clockwise, press ENTER to save...
  • Seite 9 DMX SETTING 12 Channels Channel Function Value Description 000-255 Y-16bit 000-255 Dimming 000-255 From dark to bright 000-255 From dark to bright Green 000-255 From dark to bright Blue 000-255 From dark to bright White 000-255 From dark to bright Strobe 000-255 From slow to fast...
  • Seite 10 17 Channels Channel Function Value Description 000-255 Y-16bit 000-255 Dimming 000-255 From dark to bright 000-255 From dark to bright Green 000-255 From dark to bright Blue 000-255 From dark to bright White 000-255 From dark to bright Strobe 000-255 From slow to fast Stand-alone/sound- 001-007...
  • Seite 11: Dmx-512 Connection

    212-241 Red + Green 242-255 Red + Green + Blue White LED 3 002-031 032-061 Green 062-091 Blue 092-121 White 122-151 Red + Green 152-181 Red + Blue 182-211 Green + Blue 212-241 Red + Green 242-255 Red + Green + Blue White LED 4 002-031 032-061...
  • Seite 12: Dmx Mode

    DMX MODE This mode allows you to use universal DMX-512 console to operate. 1. Install the units in a suitable position. 2. Use standard XLR cable to connect your units together via the XLR connector on the rear of the units. For longer cable we suggest a terminator at the last fixture.
  • Seite 13: Technical Specification

    TECHNICAL SPECIFICATION Rated voltage : AC110~240V 50/60Hz Rated power : 120W 5x 10W RGBW 4in1 Control Signal : DMX signal DMX Channel : 12/17 Channels Function : DMX, Auto, Sound active and Master-Slave. Dimensions per unit : 85 x 600 x 165mm Weight (per unit) : 7.15Kg The specifications are typical.
  • Seite 15 Fax : 0031546589298 The Netherlands Product number: 150.516 Product Description: MHL510 LED Beam Bar 5x 10W Quad Regulatory Requirement: EN 60598-1/-2-17:2009 EN 55015:2007 EN 61547:2009 EN 61000-3-2/-3-3 The product meets the requirements stated in Directives 2006/95 and 2004/108/EC and conforms to the above mentioned Declarations.