MAINTENANCE
Regularly check the battery for damage.
TECHNNICAL DATA:
Operating voltage
Switch voltage
Switch outlet switching capacity
Wireless signal range
Operating frequency
Ambient temperature
Storage temperature
Battery
EC-compliant

FAULT RECTIFICATION

Fault
Function lamp (4) does
not illuminate when a
button is pressed.
Function lamp (6)
does not illuminate
Function lamp (6) does
not illuminate, device
does not work.
18
RCS 1000 N Comfort
230 V~ 50 Hz
230 V~ 4.35 A
max. 1000 W
max. 25 m
433.92 MHz
0 ° to 35 °C
- 40 ° to 70 °C
12 Volt, Type A 23
Cause
Battery incor-
rectly inserted.
Battery does not
have contact.
Battery is empty. Insert a new
Switch outlet not
properly
connected.
Device not swit-
ched on.
Repair
Insert the bat-
tery correctly.
Press the battery
against the con-
tact terminals.
battery.
Plug the switch
outlet firmly
into the outlet.
Switch on the
device.

Quicklinks ausblenden: