Herunterladen Inhalt Inhalt Diese Seite drucken

Service And Repairs; Troubleshooting; Technical Data - Aventics NL1 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für NL1:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
AVENTICS | NL1 / NL2 / NL4 / NL6 | R412015553–BAL–001–AC | English
Sudden surge in pressure during start-up!
If no SSU filling unit is used, the system will suddenly be
under pressure during start-up. This could cause
dangerous and sudden cylinder movements.
O When starting up a system without the SSU filling
unit, make sure that the cylinders are in their end
position. For cylinders not in the end position, make
sure they do not present any danger.
Assembling the mounting elements
W01
W06
O Observe the figures
Assembling the pressure sensor
3
Flange mounting (only with DIL distributor/
narrow; not with NL1)
1. Remove the blanking screw (a).
2. Insert the O-ring (b) into the sealing groove (c).
3. Mount the pressure sensor (d) onto the flange and
tighten it.
4
Pipe connection
1. Remove the blanking screw (a).
2. Mount the seals (d) onto the double nipple (b).
3. Screw the pressure sensor (e) onto the double nipple.
6

Service and Repairs

Cleaning and servicing
W
Seal all openings with suitable protective caps to
prevent detergents from penetrating the system.
W
Never use solvents or strong detergents. Only clean
the product using a slightly damp cloth. Only use water
and, if necessary, a mild detergent.
W
Do not use high-pressure cleaners for cleaning.
W
Do not use compressed air for cleaning (blowing off)
maintenance units or maintenance devices.
CAUTION
W06
.
W01
7
Decommissioning,
Disassembly, Exchange
Danger of injury if disassembled or exchanged under
pressure or voltage!
Disassembly or exchange when under pressure or
electrical voltage can lead to injuries and damage to the
product or the system components.
O Make sure that the relevant system part is not under
pressure or voltage before disassembling the
product or exchanging parts.
O Protect the system against being switched on.
8
Disposal
Scrap the device and fluid in accordance with local
regulations.
9

Troubleshooting

Malfunctionin
Possible cause Remedy
g
Pressure/flow
Working
level is not
pressure too
reached or
low
slowly
decreases.
Leakage in the
tubing

10 Technical Data

Maximum permissible pressure, temperature range, and
thread connection are indicated on the product.
General data
Mounting orientation
For further technical data, please see the online
catalog at www.aventics.com/pneumatics-catalog.
CAUTION
Set a higher working
pressure
Check tubing
diameter
Check tubing and its
fittings
Any
6

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Nl2Nl4Nl6

Inhaltsverzeichnis