3. CONNECTION TO DRAINAGE
Drainage should be located lower to the machine level, at 150 mm (5.91 inches) minimum.
It is convenient that the drainage pipe is of 30 mm (1.18 in) of interior diameter and with a
minimum gradient of 3 cm (1.18 in) per meter (see figure).
Descending
1. WATER AND DRAINAGE
Water quality has a remarkable influence on the appearance,
hardness and flavor of the ice as well as, on the machines
condensated by water, on the life of the condenser.
2. CONNECTIONS TO THE WATER
NETWORK
Use a flexible pipe (1.3 m – 4.27 feet length) with the two filter
joints supplied with the machine. We strongly discourage the
use of two-exit bibs and two switches as, due to an error
could close that back one, leaving the machine without water
supply. This could result on a damage call without actually
existing one.
Pressure should be established between 0.7 and 6 Kg/cm
/ 85 psi.)
If pressures overpass such values, install the necessary
corrective devices.
INSTALL A 10 µ PARTICLE FILTER INCLUDED IN THE
KIT.
CORRECT
Ascending
INCORRECT