SKY

Configuring the functions

ON
OFF
1 2 3 4 5 6
Einstellregler:
1. Time control
for water arrest, default set-
ting 1 min (setting range 30 s
to 10 min).
3. DIP switches:
Function activation – DIP switch 1–6:
DIP switch
Function
1
Flushing mode
2
Cleaning stop
3
Continuous flow
4
Stagnation rinse
5
Stagnation rinse time
6
Shut-off delay (ON = 5 s, OFF = 3 s)
1
Time control
2
Sensitivity control
3
DIP switches
Move counterclockwise to decrease the setting.
Move clockwise to increase the setting.
2. Sensitivity control
regulates the shut-off sensiti-
vity of the fitting (1 = sensitiv,
20 = insensitiv)
Rule applies to all controls:
Factory setting
ON
OFF
OFF
OFF
OFF
OFF
WimTec SKY
Washbasin fitting
EN
Position of the
touch sensor
!
Description
Page 19
Page 19
Page 20
Page 21
Page 21
Page 22
15