2 Instrument Setup

Selecting units of measure

The F210 will indicate fuel values in Litres, Imperial
gallons or US gallons. To change the current setting
perform the following steps:
1. Power up the unit while holding down the
key.
FLOW
Hold down during power up
2. When the unit is on, release the
display will indicate the current display unit
with:
8 U1
8 U 2
8 U 3
3. To select the display unit desired, use the
and
keys to change the value.
4. To exit this mode, press and hold both the
and
keys simultaneously for one second.
Press and hold to exit
Information will now be indicated in the selected
display unit.
6
TOTAL
key. The
Imperial Gallons
US Gallons
Litres
Northstar
F210 Installation and Operation Manual

Calibration

The fuel transducer supplied with the fuel flow meter
will provide readings at better than 5% accuracy.
Individual calibration will increase this level of ac-
curacy to better than 2% over a fuel flow range of
10.0 to 120 litres per hour. Use the following steps
to calibrate your fuel flow meter:
1. Reset the total log value to zero (see previous
page).
2. Use a known amount of fuel. The larger the
amount the more accurate the calibration will
be.
3. Take note of the actual volume of fuel used
and the fuel used indicated by the total log. If
these two totals are different the instrument
may require calibration.
4. Press and hold the
power
L
A
T
O
Hold down during power up
5.
Release the
total log value.

6. Use the
or
indicate the actual volume of fuel used.
7. Press both keys simultaneously for 1 sec to
exit.
Press and hold for 1 second
The fuel flow meter is now calibrated.
key while applying
T
W
O
L
F
key. Display will flash current
keys to make the display