Herunterladen Inhalt Inhalt Diese Seite drucken
Vorschau ausblenden Andere Handbücher für NEXUS serie:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

PART NUMBER
SERIAL NUMBER
NEXUS Generator & Multi-head Inflator User Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Safety Guidelines
This manual contains information that is very important to know
and understand. This information is provided for safety and to
prevent equipment problems. To help recognise this information,
observe the following symbols.
Danger indicates an imminently hazardous
situation which if not avoided WILL result
in death or serious injury.
Warning indicates a potentially hazardous
situation which if not avoided, COULD
result in death or serious injury.
Caution indicates a potentially minor or
moderate injury.
Notice indicates important information,
that if not followed, may cause damage to
equipment.
Unpacking
After unpacking the unit, inspect carefully for any damage that
may have occurred during transit.
Do not operate unit if damaged during
shipping, handling or use.
General Safety Information
The operator of this product must take the necessary precautions
to prevent the level of danger indicated by these symbols. The
operator is required to read and understand this instruction
manual and all safety warnings, labels etc.
Any employer allowing the use of this product in their field of work
must distribute this instruction manual to all users. The employer
must also ensure all users read, understand and follow the
instructions as described in the manual, safety warnings, labels,
etc.
76411 Issue 2
www.pclairtechnology.com
Actual decal may vary by individual part number.
Read and understand all safety warnings
and instructions before operating this
product. Failure to read and follow all
safety warnings may result in serious
personnel injury or death. Property
damage and/or product damage may also
occur if all warnings are not followed.
1.
Do not expose the product to flammable gases,
vapours or fumes
2.
Do not store flammable gases in or near this product
3.
Never use flammable or toxic solvents to clean the
product or any of the unit's parts
4.
Never remove or alter any safety warning labels, tags,
etc. located or provided with product.
5.
Follow all directions for maintenance.
The use of other than genuine PCL
replacement parts may result in reduced
equipment performance. Repairs must be
performed by authorised repair personnel,
otherwise the warranty will be void.
Image shown is PCL standard decal.

Werbung

Inhaltsverzeichnis
loading

Inhaltszusammenfassung für PCL NEXUS serie

  • Seite 1 Follow all directions for maintenance. Any employer allowing the use of this product in their field of work The use of other than genuine PCL must distribute this instruction manual to all users. The employer replacement parts may result in reduced must also ensure all users read, understand and follow the equipment performance.
  • Seite 2: General Specifications

    NEXUS Generator & Multi-head Inflator user manual General Specifications NEXUS Max inlet Min inlet supply Recommended Max inflation Min inflation Display Units of variant supply supply pressure pressure resolution measurement NEX2/MQ 145psi/10bar/ 130psi/9bar/ 14.5psi/1bar/100kPa 90psi/6.3bar/ 4psi/0.3bar/ 1psi /0.1bar/ psi/bar/kPa 1000kPa 900kPa above max set 630kPa...
  • Seite 3 NEXUS Generator & Multi-head Inflator user manual 3. Attachment of pneumatic pipe to the filtration unit. 1. Install filter-regulator (ATC12). Pipe A is attached to the right hand side of the filter-regulator via a Remove filter-regulator unit and dial gauge from packaging and push in fitting.
  • Seite 4 NEXUS Generator & Multi-head Inflator user manual General Specifications System set-up instructions Fig 9 1. Connect to air supply by screwing your chosen adaptor to the Rp 1/4 fitting (1/4 NPT for US versions) into the compressed air inlet port, See Fig. 7. Then connect your air supply coupling end to the adaptor.
  • Seite 5: Operation

    NEXUS Generator & Multi-head Inflator user manual For purge cycle follow the below Operation steps Follow the below sequence for purging the tyres. Switch on the Inflator Generator by pressing the button on the front of Set Target pressures for front and rear wheel. the unit, shown in Fig.
  • Seite 6: Emergency Stopping

    Turn the unit on and off to restart the ‘set up’ process switch. When you see ‘PCL’ displayed on both top left and top right When the unit is running its start up checks you will see controller screens press the + and - buttons simultaneously ‘PCL’...
  • Seite 7 NEXUS Generator & Multi-head Inflator user manual For inspection and checking of The PCL tyre inflators are exclusively approved for the dispensing of air/N . Each use which doesn't follow this the actual tyre pressure: purpose as well as modifications to the product will be Simultaneously depress + and - keys together (long deemed to be improper use.
  • Seite 8: Unit View

    NEXUS Generator & Multi-head Inflator user manual Unit view Fig 14 LCD Display Front tyres control panel Rear tyres control panel Filter-regulator unit N2 Tank pressure Valve cap tray Nitrogen purity test point On/Off switch Handles Hose hooks Auxiliary port 4 individual exhausts 90mm castors...
  • Seite 9 Gauge and is designed to identify the purity of Nitrogen being produced by the machine. To identify the purity of Nitrogen being produced simply remove the valve cap and push the connector on a PCL Nitrogen Analyser unit (N2A001) which will automatically give you a purity readout. Fig 16 Auxilliary Port This is located on the bottom of the left hand side of the unit.
  • Seite 10 NEXUS Generator & Multi-head Inflator user manual Trouble Shooting Guide/Error Messages Problem Possible Cause Solution No display No power connected Switch power on No inflation process Tyre is below 3 psi Press flat tyre button Faulty connector Replace faulty connector Buzzer does not sound Buzzer volume has been turned off Turn buzzer on...
  • Seite 11 FITNESS FOR A PARTICULAR PURPOSE. Determination of the suitability of the unit for the use contemplated by the customer is the sole responsibility of the customer. PCL shall not, under any circumstances, be liable in contract, tort or otherwise (including negligence and strict liability) for indirect, special, incidental, or consequential damages, and PCL's total liability shall not exceed the net purchase price for the unit.
  • Seite 12: Calibration Certificate

    Calibration Certificate Each unit, before release, is checked and calibrated on test equipment that has accuracy traceable to Druck pressure indicator S/N2329290. The Druck unit is referenced to Certificate 0029346 issued by UKAS Laboratory No. 0221. This accuracy exceeds EC Directive 86/217/EC and BS EN 12645:1999 (MPE = 0.08 bar). Inflator Head Location Bottom Bottom...
  • Seite 13: Nexus Bedienungsanleitung Nexus Generator Und Mehrkopfpumpe

    Situation hin, die bei Nichtvermeidung zum Tod oder zu schweren Verletzungen führen könnte. 'Vorsicht' weist auf eine potentielle Die Abbildung zeigt die Standard-Ausführung von PCL.. mittelschwere oder geringe Verletzung Das tatsächliche Erscheinungsbild kann je nach Teilenummer abweichen. hin. Vor der Inbetriebnahme dieses Produktes müssen alle Sicherheitswarnhinweise und...
  • Seite 14: Allgemeine Spezifikationen

    NEXUS Bedienungsanleitung NEXUS Generator und Mehrkopfpumpe Allgemeine Spezifikationen NEXUS- Max. Min. Empfohlene Versorgung Max. Be- Min. Be- Display- Messeinheiten Variante Eingangsver- Eingangsver- triebsdruck triebsdruck Auflösung sorgung sorgung NEX2/MQ 12 bar 9bar 1 bar über max. 6.3bar 0.3bar 0.1bar eingestelltem Druck des Reifenfüllgeräts NEX6/MQ 12 bar...
  • Seite 15 NEXUS Bedienungsanleitung NEXUS Generator und Mehrkopfpumpe 1. Installation des Filter-Reglers (ATC12). Nehmen Sie den Filter-Regler und die Skalenscheibe des 3. Befestigung der Druckluftleitung an der Filtereinheit. Druckmessers aus der Verpackung. Bringen Sie PTFE-Band auf Leitung A wird mit einer Einschubarmatur rechts am Filter-Regler dem Gewinde der Skalenscheibe an, bevor Sie sie in die befestigt.
  • Seite 16 NEXUS Bedienungsanleitung NEXUS Generator und Mehrkopfpumpe Allgemeine Spezifikationen Anweisungen zur Systemeinrichtung Abb. 9 1. Schließen Sie das Gerät an die Luftzufuhr an. Schrauben Sie dazu Ihr gewähltes Anschlussstück an den Rp-1/4-Anschluss (1/4 NPT bei US-Versionen) in den Drucklufteinlass, siehe Abb. 7. Verbinden Sie dann die Muffe der Luftzufuhr mit dem Anschlussstück.
  • Seite 17 NEXUS Bedienungsanleitung NEXUS Generator und Mehrkopfpumpe Betrieb Für Ablasszyklus die folgenden Schritte Pumpgenerator durch Drücken der Taste an der Vorderseite des Geräts befolgen einschalten, siehe Abb. 9 Zum Ablassen von Luft aus den Reifen den folgenden Ablauf befolgen Auf der LCD-Anzeige erfolgt ein Prüfdurchlauf. Während des Prüfdurchlaufs Einstellen der Drücke für Vorder- und Hinterreifen zeigt der Folgeregler 'SYN' an und es erfolgt eine Synchronisierung mit den Hauptreglern.
  • Seite 18: Einstellen Von N

    Während die Einheit hochfährt und Tests durchläuft, ist auf dem ops lässt sich zwischen 0 und 2,00 bar einstellen = hiermit ist es Bildschirm ‘PCL’ zu sehen. Die äußere rechte Taste innerhalb von 2 möglich, den Fülldruck um den eingestellten Wert zu Sekunden ab Erscheinen von 'PCL' drücken.
  • Seite 19: Inspektion Und Überprüfung Des Tatsächlichen Reifendrucks

    NEXUS Bedienungsanleitung NEXUS Generator und Mehrkopfpumpe Inspektion und Überprüfung des Reifenfüllgeräte von PCL ist ausschließlich für die Abgabe tatsächlichen Reifendrucks: von Luft/N zugelassen. Jegliche Verwendung, die diesem Zweck nicht entspricht, sowie jegliche Änderungen am Drücken Sie die Tasten + und - gleichzeitig (es ertönt ein Produkt gelten als unsachgemäße Verwendung.
  • Seite 20 NEXUS Bedienungsanleitung NEXUS Generator und Mehrkopfpumpe Geräteansicht Abb. 14 Steuertafel Vorderreifen Steuertafel Hinterreifen Filterregler-Einheit N2-Tankdruck Kontrollpunkt für Reinheit des Stickstoffs Ventilkappenmulde Ein-/Ausschalter Schlauchhaken Griffe 4 individuelle Auslassöffnungen Hilfsanschluss 90-mm-Rollen Ausgangsschlauchanschlüsse www.pclairtechnology.com...
  • Seite 21 NEXUS Bedienungsanleitung NEXUS Generator und Mehrkopfpumpe NUR FÜR GESCHULTE TECHNIKER Stickstoff-Druckmessgerät Sie können die Unterlagen zur Systeminstallation und die Dieses befindet sich an der Geräteseite und gibt den Druck des Schaltpläne in einer Dokumentenmappe unterbringen. Hierzu muss Stickstofftanks im Gerät an (Abb. 15). die Luftzufuhr des Geräts getrennt werden.
  • Seite 22: Fehlerbehebung/Fehlermeldungen

    NEXUS Generator & Multi-head Inflator user manual Fehlerbehebung/Fehlermeldungen Problem Mögliche Ursache Lösung Keine Anzeige Keine Stromversorgung angeschlossen Schalten Sie die Stromzufuhr ein Kein Füllvorgang Reifen liegt unter 3 psi Drücken Sie die Taste Platter Reifen Defektes Verbindungsstück Tauschen Sie das defekte Verbindungsstück aus Summer gibt keinen Signalton ab Summer wurde stumm geschaltet Schalten Sie den Summer ein...
  • Seite 23 Gebrauch des Geräts und von der strikten Einhaltung aller Anweisungen und Empfehlungen von PCL zur Installation, zum Betrieb und zur Wartung durch den Kunden abhängig. Die beschränkte Garantie gilt nicht für Geräte oder Teile, die durch unsachgemäßen Umgang, Wartung, Lagerung, Gebrauch oder Betrieb beschädigt werden oder kaputt gehen und erstreckt sich nicht auf normalen Verschleiß, Korrosion oder Erosion.
  • Seite 24: Kalibrierungszertifikat

    Kalibrierungszertifikat Jedes Gerät wird vor der Freigabe auf den entsprechenden Testanlagen geprüft und kali- briert, deren Genauigkeit auf Druckanzeiger S/N2329290 zurückzuführen ist. Auf das Druckgerät wird in Zertifikat Nr. 0029346, ausgestellt vom UKAS-Labor Nr. 0221, Bezug genommen. Diese Genauigkeit übertrifft die Vorgaben der EG-Richtlinie 86/217/EG und BS EN 12645:1999 (MPE = 0,08 bar).

Diese Anleitung auch für:

Nex2/mqNex4/mqNex6/mq

Inhaltsverzeichnis