ou should a x the hood to a wall of su cient weight-bearing capacity, so not to one
made of plasterboard.
T
he cooker hood must be placed at a minimum distance of 65 cm from the cooking
plane for electric cookers and 65cm for gas or mixed cookers. If the instructions for
installation for the gas hob specify a greater distance, this has to be taken into account.
Do not tile, grout or silicone this appliance to the wall. Surface mounting only. Do not
x chimney ue to furniture or y over shelves unless the chimney ue can be easily
removed, in case maintenance is ever required.
T
he cooker hood is provided with an upper air exit B for discharging fumes externally
for models including chimney ue C ( Suction Version A- exhaust pipe not supplied). If
cooking fumes and vapours cannot be externally discharged, the cooker hood can be
used in the recirculating version F: the installation of 1 active charcoal lter F allows the
recirculation of fumes and vapours through the upper grid G.
M
ake sure that there is a power socket near the hood and that the system has a 30 mA
di erential. The mains voltage must be the same as that on the label inside the hood. The
hood has a 1250 mm power cable with or without plug: if it does have a plug, connect
the hood to an accessible approved socket; or if it does not (connection direct to the
mains), t an approved bipolar switch with a minimum contact opening of no less than
3 mm (accessible). This installation and electrical connection must be executed by a
quali ed technician.
I
f the cooking top is in use, the cooker hood must always operate.
P
roduct performance test carried out in accordance with standard (EU) No 65/2014-
Ref: IEC 61591
Maximum performance is achieved by placing the mobile panels, if any, in the open
position.
WARNINGS
5
GB