Alert messages
fig. o A, page 16.
E.g. see
Alert message
Description
!ALERT - Lid open
Lid open more
> 3 min
than 3 minutes
!ALERT - Voltage
The device has
low
stopped working
on DC due to low
voltage
Warning codes
fig. o B, page 16.
E.g. see
Warning code
Fault
!WARNING 32
Fan over-current
!WARNING 33
Compressor start
fail
!WARNING 34
Compressor
speed low
!WARNING 35
Controller over-
temperature
EN
Possible cause
Lid not fully
latched
Internal fault
Insufficient supply
voltage
Battery voltage is
too low
Battery protec-
tion is set too high
Possible cause
Internal fault.
High ambient
temperature
Air vent blocked
or insufficient
clearance
Internal fault
Troubleshooting
Suggested remedy
Check lid latched fully
Authorised repair centre
inspection required
Check voltage drop
from battery to power
outlet and increase wir-
ing gauge if necessary
Test the battery and
charge as needed
Select a lower battery
protection setting
Suggested remedy
Turn off the device for at
least 5 mins., then restart. If
the problem persists,
authorised repair centre
inspection required
Turn off the device for at
least 30 mins., or move
to a cooler location,
then restart
Clear the vents
Authorised repair centre
inspection required
35