nearest authorized technical assistance center. Always use the same type of spare parts.
Make sure the power cord is never crimped or damaged.
Never disconnect the power cord by pulling or tugging on the cord.
Avoid direct eye exposure to the light source while it is on as sensitive persons may suffer an epileptic shock
(especially meant for epileptics)!.
The product is for decorative purposes only and not suitable as a household room illumination.
If the mains cable of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his ser-
vice agent or a similar qualified person in order to avoid a hazard.
The light source of this luminaire is not replaceable. When it reaches the end of its life time, the whole unit
must be discarded.
DISCONNECT DEVICE
Where the MAINS plug or an appliance coupler is used as the disconnect device, the disconnect device shall
remain readily operable.

INSTALLATION

The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to
avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the
unit is secure and is able to support a weight of 10 times of the unit's weight.
Never stand directly below the device when mounting, removing or servicing the fixture.
FIXTURE LINKING
You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to run
synchronized shows on two or more fixtures set to a master/slave operating mode. The combined number of
channels required by all fixtures on a serial data link determines the number of fixtures that the data link can
support.
Important: Fixtures on a serial/data link must be daisy chained in one single line. Maximum recommended
serial data link distance: 100 meters (1640 ft.) Maximum recommended number of fixtures on a serial data link:
16 fixtures
DATA CABLING
To link fixtures together you must use data cables. If you choose to create your own cable, please use da-
ta-grade cables that can carry a high quality signal and are less prone to electromagnetic interference.
CABLE CONNECTORS
Cabling must have a male XLR connector on one end and a female XLR connector on the other end.
DMX connector configuration
Termination reduces signal errors. To avoid signal transmission problems and inter-
ference, it is always advisable to connect a DMX signal terminator.
CAUTION
Do not allow contact between the common and the fixture's chassis ground.
Grounding the common can cause a ground loop, and your fixture may perform
erratically. Test cables with an ohm meter to check correct polarity and to make
sure the pins are not grounded or shorted to the shield or each other.
LED DISPLAY
The LED display has 4 buttons: MENU / UP / DOWN / ENTER
Switch the unit on, press MENU to enter into the SUB-MENUS, press UP/DOWN (+/-) to
choose a sub-menu, then confirm your choice with ENTER.
4
MANUAL - PARLED-54
©Copyright LOTRONIC 2019
8.8.8.8.
MENU
UP
DOWN
ENTER