Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 7
The filter must be cleaned by reverse rinsing regularly,
at least every 2 months
Non-compliance can lead to the filter becoming blocked
This results in a drop in pressure and decreased water
flow
The filter meshes are made of stainless steel. A red
coating as a consequence of rust from the pipelines has
no influence on function or the way the filter works
Do not forget to do a visual check of the ball valve.
Replace if it is dripping!
8.2 Maintenance
8.2.1Replace filter insert
1.
Close shut-off valve on inlet
2.
Release pressure on outlet side (e.g. through water tap)
3.
Close shut-off valve on outlet
4.
Unscrew filter bowl
5.
Remove filter insert
6.
Insert new filter insert
Put on the O-ring
7.
Put new O-ring on filter bowl
8.
Screw filter bowl in place
9.
Slowly open shut-off valve on inlet
10. Slowly open shut-off valve on outlet

10 Troubleshooting

Problem
Too little or no water pressure
Increased differential pressure between
inlet and outlet pressure gauge
MU0H-1178GE23 R0519
GB
8.2.2Replace filter mesh
1.
2.
3.
4.
5.
6.
7.
8.
9.
10. Put new O-ring on filter bowl
11.
12. Slowly open shut-off valve on inlet
13. Slowly open shut-off valve on outlet
8.2.3Replace ball valve
1.
2.
3.
4.
5.
6.
7.
8.
9.
9
see chapter 4 Scope of Delivery
Cause
Shut-off valves upstream or downstream
from filter not fully open
Filter mesh dirty
Filter is not fitted in flow direction
Reverse rinsing interval is exceeded
High degree of dirt in the water
5
Close shut-off valve on inlet
Release pressure on outlet side (e.g. through water tap)
Close shut-off valve on outlet
Unscrew filter bowl
Remove filter insert
Dismount filter insert
Replace filter mesh
Mount the filter insert
Put filter insert into filter bowl
Screw filter bowl in place
Close shut-off valve on inlet
Release pressure on outlet side (e.g. through water tap)
Close shut-off valve on outlet
Unscrew discharge connection
Remove ball valve
Screw in new ball valve
Screw in discharge connection
Slowly open shut-off valve on inlet
Slowly open shut-off valve on outlet
Disposal
Observe the local requirements regarding correct
waste recycling/disposal!
Remedy
Open the shut-off valves fully
Reverse rinsing
Fit filter in flow direction
Reverse rinsing
Reverse rinsing
Decrease reverse rinsing interval
Replace filter sieve

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis