Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specifications; Installation - Erone 750W Plus Bedienungsanleitung

Funkmotorsteuerung
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

1 - INTRODUCTION
The receiver Erone 400 W is a radio programmer which can drive
directly an asynchronous 230 Vac AC motor with max power of
400 W. The operating frequency and the coding system are
different, depending upon the model.
The following table summarises the range of radio programmers,
pointing out series, frequency and coding system:
SERIES
TYPE
ERONE 024A SEL 2641R433P4
ERONE 30(DP/SL) SEL 39R30P4
ERONE DS433
SEL 39R433P4
ERONE 028A SEL 2681R868P4
Depending upon the frequency and the coding, the receiver
operates with different transmitters, according to the following
table:
Receiver Type
Usable transmitter
SEL 2641 R433P4 S2TR2641E2/E4
SETR2641AM2
SETR2641-TM
SEL2681 R868P4
S2TR2681E2/E4
SEL 39 R433P4
SETDS39433 E2/E4
SEL39 R30P4
SETL 39E2/E4
SETD 39E2/E4

2 - TECHNICAL SPECIFICATIONS

Type
SEL 2641R433-P4 / SEL2681R868-P4
Receiver type
Carrier frequency
Local oscillator frequency
Modulation
Input load
Channel width
Intermediate frequency
Input sensitivity
Local oscillator emissions
Power voltage
Motor maximum power
Memory capacity
Operating temperature
IP grade
Weight
Overall dimensions
Type
SEL 39R433-P4 / SEL39R30-P4
Receiver type
Carrier frequency
Local oscillator frequency
Modulation
Input load
Channel width
Intermediate frequency
Input sensitivity
Local oscillator emissions
Power voltage
Motor maximum power
Memory capacity
Operating temperature
IP grade
Weight
Overall dimensions
ENGLISH
FREQUENCY
CODING
433.92 MHz
Rolling code
30.875 MHz
Dip/Self learning
433.92 MHz
Dip-switch
868.30 MHz
Rolling code
Superheterodyne
433,92 / 868,30 MHz
6,6128 / 13,399 MHz
AM/ASK
50 Ohm
> 25 KHz
10,7 MHz
-115 dBm
< -57 dBm
230 Vac
400 W
85
-20°/+70°C
IP44
380 gr.
140 x 115 x 52 mm
Superheterodyne
433,92 / 30,875 MHz
6,6128 / 30,420 MHz
AM/ASK
50 Ohm
> 25 KHz
10,7 Mhz / 455 KHz
-115 / -117 dBm
< -57 dBm
230 Vac
400 W
100
-20°/+70°C
IP44
380 gr.
140 x 115 x 52 mm
3 - FUNCTIONALITY
Sequential (or cyclic):
1 Pulse opens
1 Pulse closes, stop with a timer
Mixed
1 Pulse opens, closing only with permanent contact.
Man present:
Opening and closing only with permanent contact (reduced
range). The motor time-out is selectable (from 6 to 186 sec) by
means of 5 dip - switches; it is used as security to avoid powering
the motor for too long after the mechanical stop.
Other features:
Local and general operating selection (with multiple motor
driving); the general command is possible only for the sequential
operating mode.
For the general mode using it is necessary to use a 4 keys
transmitter of the same range.
It possible to connect an external push button or a key - contact to
complete the radiocontrol.
The memory capacity is 85 or 100 transmitters.

4 - INSTALLATION

Positioning
The local choice is very impotant for the best result of the installation.
The following conditions have to be followed:
- Fix the radioprogrammer far from the interference sources as
informatic systems, alarm systems or other radio emissions.
- The distance between 2 receivers should be greater of 1.5 mt.
Fixing
Remove the cover of the receiver; fix the box in each corner by
using the screws and the plugs supplied.
Connections
1- Connect the power supply (230 Vac) to the terminal blocks (fig.
10):
terminal 1 = PH phase
terminal 2 = N neutral
terminal 6 = earth
1
2
Ph N
2 - Connect the motor to the terminal blocks (fig. 11):
terminal 3 = C common
terminal 4 = O open
terminal 5 = CL close
terminal 7 = GND ground
Connect the capacitor between terminals 4 and 5.
3 4 5
C O CL
Fig.10
6
Fig. 11
7
Pag. 7

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis