Safety advices:
 Installation and repairs to the equipment may only be carried out by
technicians observing the current VDE guidelines. No liability will be
assumed in the case of faulty installation and commissioning.
 Before opening the equipment pull out the power plug or remove the
power supply, otherwise there is danger of electrocution. This is also
valid for cleaning the equipment or working on the connections.
 Only use the mains cable connected to the device. Never replace any
parts or make any modifications on the mains cable. Otherwise there is a
risk of mortal injury for which we cannot be held liable.
 Providing that a serviceable fuse exists, the power cord must be pulled
out before changing the fuse. Defective fuses may only be replaced with
standard compliant fuses that have the same nominal value.
 The equipment may only be operated in dry rooms. In humid rooms
or outdoors there is danger of short-circuit (caution: risk of fire) or
electrocution.
 Choose the location of installation or mounting so that the power plug
can be reached and pulled out of the socket easily in case of danger.
Choose the location of installation or mounting such that children may
not play unsupervised near the equipment and its connections. The
location of installation or mounting must allow a safe installation of all
cables connected. Power feeding cables as well as feeder lines may not
be damaged or clamped by objects of any kind. To prevent damage to
your equipment and to avoid possible peripheral damages, the devices
foreseen for wall mounting may only be installed on a flat surface.
 Choose a location of installation or mounting which complies to the
protection class IP 54.
 Avoid exposure of the equipment to direct sunlight and to other heat
sources (e. g. radiators. other electrical devices, chimney, etc.). Devices
that are equipped with heat sinks or ventilation slots must under no
circum-stances be covered or blocked. Also ensure for a generous
air circulation around the equipment. In this way you avoid possible
damage to the equipment as well as a risk of fire caused by overheating.
Absolutely avoid that cables come near any source of heat (e.g.
radioators, other electrical devices, chimney, etc.).
State of the art 2019-11-26
Technical improvements, changes in design, printing- and other errors expected.
Technical data:
Typ
EMC
Downstream
Frequency range
Gain
Max. output level CSO/CTB
(CENELEC raster, 41/42 ch. 60 dB IMA)
Attenuation: adjustable in 1 dB steps
Equalization: adjustable in 1 dB steps
Attenuation interstage: pluggable with jumpers
Equalization interstage: pluggable with jumpers
Return loss
Noise figure typ.
Upstream
Frequency range
Gain
Attenuation: adjustable in 1 dB steps
Equalization interstage: pluggable with jumpers
Attenuation interstage: pluggable with jumpers
RF connectors
Type
Test port at in-/output
General
Switching power supply
Power indicator
Power consumption
Equipotential bonding connection
Operating temperature range
(acc. to EN 60065)
Dimensions (W × H × D) appr.
Protection class
Herewith AXING AG declares that the marked products comply with the valid
guidelines.
WEEE Nr. DE26869279 | Electrical and electronic components must not be
disposed of as residual waste, it must be disposed of separately.
Manufacturer
EEA contact address
AXING AG
Bechler GmbH
Gewerbehaus Moskau
Am Rebberg 44
8262 Ramsen
78239 Rielasingen
BVS01466
according to EN 50083-2, Class A
85...1006 MHz
40 dB
111 dBµV
BVS 14-66
0...15 dB
0...15 dB
premium-line
0 | 2 | 4 | 6 dB
0 | 2 | 4 | 6 dB
≥ 18 (-1,5 dB/Okt.)
CATV amplifiers
<7dB
5...65 MHz
Operation instructions
30 dB
0...15 dB
0 | 3 | 6 | 9 dB
0 | 6 dB
CFA 12-00/CKA 12-00
-20 ±2,5 dB/-20 ±1,0 dB
30...65 VAC / 50...60 Hz
LED
14 W
4 mm²
-20...+50°C
182 × 146 × 71 mm
IP 54