Problem
No water outlet
Reduced flow rate
Wrong supply of mixed
water
Water flows constantly
Wrong time flow rate (too
short or too long)
Obtain the correct inlet pressures and adjust them to 3 bar.
Don't squeeze or bend the hoses.
The taps must be installed by qualified technician.
Mandatory installation of the filter seals – the installation of stop valves makes the access to
maintenance easier.

Troubleshooting

Cause
Stop valves are closed
Filters are clogged
Hoses are twisted or bent
Mixer blocked in anti-scald security – cold water
failure
Filters are clogged
Stop valves are not opened enough
Hoses are twisted or bent
Pressure is too low
Cartridge has been improperly configured
Cartouche is obstructed or dirty
Flow aerator obstructed
The pressions of hot and cold water are unbalanced
The temperature difference between cold and hot
water is too low
Hoses are twisted or bent
Stop valves are not opened enough
Connection warm and cold water inverted
Cartridge is obstructed or dirty
Cartridge out of order
Wrong position of the limiter
Reduced flow rate
Important informations
Solution
Open the stop valves
Clean or replace
Connect correctly the hoses
Check pressure presence
Clean or replace
Open the stop valves
Connect correctly the hoses
Check the pipelines
Adjust the cartridge (see page ......)
Clean or replace
Clean or replace
Find the good pressure balance;
ΔP < 1bar
Check the water inlets
Connect correctly the hoses
Open the stop valves
Check the connections
Clean or replace
Replace
Adjust the flow time limiter (see
page......)
See « Reduced flow rate »