Safety advices:
 The installation of the device and repair work on the device must be carried
out only by a professional in accordance with the applicable VDE directives.
In case of incorrect installation, no liability is assumed.
 Never open the device. There are no parts to be maintained by the user inside
the device, however, lethal voltages are present. This also applies to cleaning
the device or working on the connections.
 Use only the mains cable enclosed to the device. Never replace any parts
or make any modifications to the mains cable. Otherwise, there is a risk of
death.
 If you intend not to use the device for a longer period of time, we recom-
mend you to completely disconnect the device from the mains for safety
reasons and for saving energy by pulling out the mains plug.
 Let the device adjust to the room temperature before commissioning, in
particular if condensation is present on the device, or if it was exposed to
large temperature fluctuations.
 The device must be operated only in moderate climate.
 The device must be operated only in dry rooms. In damp rooms or outdoors,
there is a risk of short-circuits (attention: risk of fire) or electrical shocks
(attention: risk of death).
 The device shall not be exposed to dripping or splashing. Do not place
objects filled with liquids such as vases on the device.
 Plan the mounting or installation location such that you can easily reach the
mains plug and interrupt the electric circuit in dangerous situations. Select
the mounting or installation location such that children cannot play near the
device and its connections without supervision. The mounting or installation
location must allow a safe installation of all connected cables. Power supply
cables and supply cables must not be damaged or squeezed by any objects.
 Operate the device only on a flat, firm surface and protect it against uninten-
tional movements.
 Never expose the device to direct solar irradiation and avoid direct vicinity of
heat sources (e.g. heaters, other electrical appliances, fireplace, etc.). It must
be always ensured that devices with cooling elements or ventilation slots are
not covered or obstructed.
 Ensure generous air circulation around the device. This will prevent possible
damage to device and risk of fire due to overheating. Mounting in a 19"
rack, there must be at least 5 cm clearance in front of and behind the unit.
 It must be always ensured that cables are not located near heat sources (e.g.
heaters, other electrical appliances, fireplace, etc.).
 In particular, the warranty and liability shall be excluded for the consequenc-
es of incorrect use, in case of incorrect modifications or repair work carried
out by the customer. Use the device only as described in the operating
instructions and in particular according to the state-of-the-art.
 The DVB-C/T/T2 network must be installed and grounded according to the
current DIN EN 60728-11 standard.
Herewith AXING AG declares that the marked products comply with the valid
guidelines.
WEEE Nr. DE26869279 | Electrical and electronic components must not be
disposed of as residual waste, it must be disposed of separately.
State of the art 2019-10-30
Technical improvements, changes in design, printing- and other errors expected.
Technical data:
Type
MIM 4-02
Supported input transport
SPTS, MPTS (CBR/VBR)
streams
Max. number of input streams
(out of SPTS or MPTS)
Supported protocols IPTV input
IP V4; UDP; RTP; IGMP v2, v3
Total net data rate IPTV input
Number of output channels
1 × 4 × DVB-T2
Output frequency range
109...862 MHz
Output channels adjustable
S2...K69
Output channel bandwidth
Output net mode
MFN
Possible frequency shift
-4...+4 MHz (0.5 MHz steps)
Output connector
Output test port
1 × F-female (–30 dB)
Outputimpedance
Output level adjustable
85...105 dBµV
Output compilance
EN 50083-9 | ETSI TS 101 154
| ETSI EN300 429 | ETSI EN
300 744
DVB-T2* acc. to EN 302 755,
mode A (single PLP)
Output modulation, modulation
QPSK, QAM16, QAM64,
type
QAM256
Supported output formats
MPEG-2/H.262, MPEG-4/H.264 and HEVC/H.265
MER
≥ 36 dB
FFT
1k, 2k, 4k mode
FEC
1/2, 3/5, 2/3, 3/4, 4/5, 5/6
Pilot pattern
PP1...PP8
Output guard interval
1/4, 1/8, 1/16, 1/32
Output symbol rate
47, 83 Mbps
Data interface IPTV intput
1 x RJ45, IEEE 802.3, 1000
Base-T (GigE)
CAS / redundant IPTV interface
1 x RJ45, IEEE 802.3, 1000 Base-T (GigE)
Configuration / CAS interface
1 × RJ-45, IEEE 802.3, 10/100 Base-T
Supported configuration
HTTP, SNMP v1, SNMP, v2c,
protocols
AXING SMARTPortal
Operating temperature range
(acc. to EN 60065)
Comments
* switchable to DVB-T by license key
Note: You find the detailed technical data by entering the article in the search
field at www.axing.com.
Manufacturer
EEA contact address
AXING AG
Bechler GmbH
Gewerbehaus Moskau
Am Rebberg 44
8262 Ramsen
78239 Rielasingen
MIM 16-00
512
1 × 900 Mbps
1 × 16 DVB-C
1 × 12 DVB-T
109...1006 MHz @ DVB-C
MIM 4-02 | MIM 16-00
109...862 MHz @ DVB-T
S2...K87 @ DVB-C
S2...K69 @ DVB-T
premium-line
7 MHz, 8 MHz
-
Extension modul
1 × F-female
75 Ω
80...105 dBµV @ DVB-C
Quick start guide
77...102 dBµV @ DVB-T
EN 50083-9 | ETSI TS 101 154
| ETSI EN300 429 | ETSI EN
300 744 | ITU-T J.83A/C
QAM32, QAM64, QAM128,
QAM256 @ DVB-C
QPSK, QAM16, QAM64 @
DVB-T
≥ 40 dB @ DVB-C
≥ 36 dB @ DVB-T
2k mode @ DVB-T
1/2, 2/3, 3/4, 5/6, 7/8 @
DVB-T
-
1/4, 1/8, 1/16, 1/32 @ DVB-T
1...7,5 MBauds/s
1 × RJ45, IEEE 802.3, 1000
Base-T (GigE)
HTTP, SNMP v1, SNMP, v2c,
AXING SMARTPortal
–10°C...+50°C

Werbung

loading

Diese Anleitung auch für:

Mim 16-00