For preferential kWh rate power
supply
Indoor unit supplied from outdoor Innengerät durch Außengerät
Normal kWh rate power supply
Only for normal power supply
(standard)
Only for preferential kWh rate
power supply (outdoor)
Outdoor unit
Preferential kWh rate power
supply contact: 16 V DC
detection (voltage supplied by
PCB)
SWB1
Use normal kWh rate power
supply for indoor unit
(2) Backup heater power supply
Only for ***
(3) User interface
Only for LAN adapter
Only for remote user interface
HCI
SWB1
(5) Ext. thermistor
SWB1
(6) Field supplied options
12 V DC pulse detection (voltage
supplied by PCB)
230 V AC supplied by PCB
Continuous
DHW pump output
DHW pump
Electrical meters
For safety thermostat
Inrush
Installationsanleitung
32
Übersetzung
Für Wärmepumpentarif-
Netzanschluss
gespeist
Normaltarif-Netzanschluss
Nur für normale
Stromversorgung (Standard)
Nur für Wärmepumpentarif-
Netzanschluss (außen)
Außengerät
Wärmepumpentarif-
Netzanschlusskontakt: 16 V DC-
Erkennung
(Spannungsversorgung durch
Platine)
Schaltkasten
Normaltarif-Netzanschluss für
Innengerät verwenden
(2) Stromversorgung für
Reserveheizung
Nur für ***
(3) Bedieneinheit
Nur für den LAN-Adapter
Nur für die spezielle Komfort-
Benutzerschnittstelle
(BRC1HHDA wird als
Raumthermostat verwendet)
Schaltkasten
(5) Externer Fühler
Schaltkasten
(6) Bauseitig gelieferte Optionen
12 V Gleichstrom
Impulserkennung (Spannung
wird durch Platine geliefert)
230 V Wechselstrom
Spannungsversorgung durch
Platine
Dauerstrom
Auslass der
Brauchwasserpumpe
Brauchwasserpumpe
Stromzähler
Für Sicherheitsthermostat
Einschaltstrom
Englisch
Max. load
Normally closed
Normally open
Safety thermostat contact: 16 V
DC detection (voltage supplied
by PCB)
Shut-off valve
SWB1
(7) Option PCBs
Alarm output
Changeover to ext. heat source
Max. load
Min. load
Only for demand PCB option
Only for digital I/O PCB option
Options: ext. heat source output,
alarm output
Options: On/OFF output
Power limitation digital inputs: 12
V DC / 12 mA detection (voltage
supplied by PCB)
Space C/H On/OFF output
SWB
(8) External On/OFF thermostats
and heat pump convector
Additional LWT zone
Main LWT zone
Only for external sensor (floor/
ambient)
Only for heat pump convector
Only for wired On/OFF
thermostat
Only for wireless On/OFF
thermostat
Übersetzung
Maximale Belastung
Öffner
Schließer
Sicherheitsthermostat-Kontakt:
16 V Gleichstrom-Erkennung
(Spannungsversorgung durch
Platine)
Absperrventil
Schaltkasten
(7) Optionen-Platinen
Alarmausgang
Umschalter zur externen
Wärmequelle
Maximale Belastung
Minimale Belastung
Nur für optionale Zusatz-Platine
Nur für die optionale digitale E/A-
Platine
Optionen: externe
Wärmequellenausgabe,
Alarmausgang
Optionen: Ausgang für EIN/AUS
Digitaleingänge für
Leistungsbeschränkung:
12 V Gleichspannung / 12 mA
Demodulation
(Spannungsversorgung durch
Platine)
Ausgang für Raumkühlung/-
heizung EIN/AUS
Schaltkasten
(8) Externer Thermostat/
Wärmepumpenkonvektor EIN/
AUS
Zusatz-Vorlauftemperaturzone
Haupt-Vorlauftemperaturzone
Nur für externen Fühler (Boden
oder Umgebungstemperatur)
Nur für Wärmepumpen-
Konvektor
Nur für verkabelten EIN/AUS-
Thermostat
Nur für kabellosen EIN/AUS-
Thermostat
ETVH/X16S18+23DA6V+9W(G)
Daikin Altherma 3 H HT F
4P586454-1 – 2019.07