Herunterladen Inhalt Inhalt Diese Seite drucken

Junction Box Pinout And Wiring - AB Quality MobileView Installationsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 15

Junction Box Pinout and Wiring

MobileView
K3
S19
6
7
8
9
10
11
1
2
3
4
5
S4
K2
1
2
3
6
* Junction Box connections are for
connection to MobileView Guard G750
Terminals only.
MobileView
Connection Cable
K1
pink
black
green-brown
white-green
grey-pink
red-blue
brown
yellow
green
grey
violet
blue
white
orange
red
To Ethernet Network
MobileView
Junction Box Cable
K3
pink
1
black
2
green-brown
3
white-green
4
grey-pink
5
red-blue
6
brown
7
yellow
8
green
12
grey
17
violet
11
9
10
K2
blue
13
white
14
orange
15
16
red
Future Use
TD+
TD-
RD+
RD-
MobileView Junction Box
Junction Box
X1
24V DC
1
GND_IN
2
E-Stop, circuit 1, pos.*
3
E-Stop, circuit 1, neg.*
4
5
E-Stop, circuit 2, pos.*
E-Stop, circuit 2, neg.*
6
Enbl. sw. circ. 1, pos*
7
Enbl. sw. circ. 1, neg*
8
Enbl. sw. circ. 2, pos*
9
Enbl. sw. circ. 2, neg*
10
11
Not used
12
Not used
S1
1
2
3
4
5
6
7
8
S2
1
2
3
4
5
6
7
8
9
S3
1
2
3
4
5
6
7
8
Publication 2727-IN006C-MU-P
7
X2
K4
+24V
1
GND
2
3
ES1+
ES1-
4
5
ES2+
ES2-
6
ED1+
7
ED1-
8
ED2+
9
ED2-
10
11
12