Herunterladen Inhalt Inhalt Diese Seite drucken

Error Messages; Technical Specifications - Antari LCU-1S Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

Step 2: Use a flat-head screwdriver to release fuse holder.
Step 3: Replace fuse with exact same type and rating as indicated below.
Step 4: Reinsert fuse holder.
Fuse
120V = T2A 250V
230V = T1A 250V

Error Messages

System
Indicates the power is not switched on.
Error
If the above message shows on the display, switch on the power of control unit or contact
your local Antari dealer for advice

Technical Specifications

Input voltage
Rated power
Fluid consumption
Compatible fluid
Ambient temp. range
Control
DMX channels
Connection
Optional accessories
Dimension
Weight
US model : AC 100-120V, 50 / 60Hz 0.35A
EU model : AC 220-240V, 50 / 60Hz 0.18A
48W
400 ml/min
Antari fluid
5 °C - 40 °C (41 °F-104 °F)
DMX512, Timer, Manual
1 channel
XLR 3-pin (DMX)
Z-8 Remote Control
SC-2 Remote Control
L203 W179 H96 mm
(L7.99 W7.05 H3.78 inch)
3.3 kg (7.28 lbs)
10

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für Antari LCU-1S