Herunterladen Inhalt Inhalt Diese Seite drucken
Vorschau ausblenden Andere Handbücher für 4-noks:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4-noks
Energy Meter 3~ RC
Installation and instruction manual
IT
EN
FR
DE

Werbung

Inhaltsverzeichnis
loading

Inhaltszusammenfassung für Astrel Group 4-noks

  • Seite 1 4-noks Energy Meter 3~ RC Installation and instruction manual...
  • Seite 3: Inhaltsverzeichnis

    Summary Manuale installazione e istruzioni d’uso ............6 Descrizione generale ....................6 Contenuto della confezione ................................6 Requisiti minimi ..................................6 Avvertenze di sicurezza ....................6 Attenzione ....................................6 Installazione ........................6 Prima dell’installazione ................................6 Fissaggio ....................................6 Collegamenti .....................................6 Prima accensione ..................................7 Verifica installazione ..................................7 Funzionamento ..................................7 Comportamento LED (tab.
  • Seite 4 Manuel d’installation et mode d’emploi ............20 Description générale ....................20 Contenu de l’emballage ................................20 Configurations minimales ................................20 Consignes de sécurité ....................20 Attention ....................................20 Installation ........................20 Avant l’installation ...................................20 Fixation ....................................20 Branchements ..................................20 Premier allumage ..................................21 Vérification de l’installation ..............................21 Fonctionnement ..................................21 Comportement LED (tableau 1) ..................22 Fonction touche (tableau 2) ..................22 Signification des numéros de bornes (tableau 3) ............22...
  • Seite 5 ZR-HM3-xx-RC Codice / Code Nome / Name Energy Meter 3~ RC ZR-HM3-50-RC Max current 50 A Energy Meter 3~ RC ZR-HM3-100-RC Max current 100 A Energy Meter 3~ RC ZR-HM3-200-RC Max current 200 A IT / Leggere e conservare queste istruzioni EN / Read and keep these instructions FR / Lisez et conservez ce manuel DE / Diese Anleitung lesen und aufbewahren...
  • Seite 6: Manuale Installazione E Istruzioni D'uso

    L’utente si assume ogni responsabilità e rischio in relazione alle fasi di installazione, configurazione e utilizzo dei prodotti per il raggiungimento dei risultati previsti dal singolo prodotto. La responsabilità di Astrel Group in relazio- ne ai propri prodotti è...
  • Seite 7: Prima Accensione

     Smart RC  “Aggiungi dispositivo Smart RC”  “Avvia procedura” e selezionare la tipologia di misura da assegnare a Energy Meter RC (Produzione/Scambio/Altro). Per maggiori informazioni: www.4-noks.com/tutorial Solo se Energy Meter RC viene utilizzato per misurare la potenza consumata da un carico (modalità Altro): accedere alla sezione “Preferenze”...
  • Seite 8: Comportamento Led (Tab. 1)

    Comportamento LED (tab. 1) Colore Stato Significato Verde Lampeggiante Frequenza proporzionale alla potenza letta attraverso i TA Non utilizzato Verde Lampeggiante Comunicazione ZigBee: dispositivo non associato con la rete Verde Fisso Comunicazione ZigBee: dispositivo correttamente associato con la rete Verde Fisso Alimentazione Verde...
  • Seite 9: Specifiche Tecniche

    Tutti i modelli sono conformi alle direttive 2014/30/UE (EMC), 2014/35/UE (LVD) e 2014/53/UE (RED). L’apparecchiatura (o il prodotto) deve essere soggetto alla raccolta separata in conformità alle vigenti normative locali in materia di smaltimento. Con la presente Astrel Group dichiara che questo prodotto è conforme ai requisiti essenziali ed alle disposizioni pertinenti stabilite dalla direttiva 2014/53/UE (RED). La dichiarazione di conformità...
  • Seite 10: 11. Schemi Installazione

    11. Schemi installazione Energy Meter per controllo consumi carico (fig. 3) Contatore Contatore di scambio di produzione L1 L2 L3 N L1 L2 L3 N Elios4you Pro + Pro Smart Interruttore generale Carico elettrico Collegamento wireless Punto verde e direzione della freccia K ...
  • Seite 11: Energy Meter Collegato Al Contatore Di Scambio (Fig. 4)

    Energy Meter collegato al contatore di scambio (fig. 4) Contatore Contatore di scambio di produzione Punto verde e direzione della freccia K  L L1 L2 L3 N verso l’interruttore generale L1 L2 L3 N Interruttore generale Utenza Elios4you Pro + Pro Smart Collegamento wireless Energy Meter 3~ RC L1 L2 L3...
  • Seite 12: Energy Meter Collegato Al Contatore Di Produzione (Fig. 5)

    Energy Meter collegato al contatore di produzione (fig. 5) Contatore Contatore di scambio di produzione Punto verde e direzione L1 L2 L3 N della freccia K  L verso l’interruttore generale L1 L2 L3 N Elios4you Pro + Pro Smart Interruttore generale Utenza Collegamento...
  • Seite 13: Installation And Instruction Manual

    The liability of the Astrel Group in respect of its products is regulated by the Astrel Group General Conditions of Sale (published on the company’s website www.astrelgroup.com).
  • Seite 14: First Power-Up

     Smart RC  “Add Smart RC device”  “Start procedure” and select the type of measurement to be assigned to the Energy Meter RC (Production/Transfer/Other) For more information: www.4-noks.com/tutorial Only if the Energy Meter RC is used to measure the power consumption of a load (Other mode): access the “Preferences”...
  • Seite 15: Response Of Leds (Table 1)

    Response of Leds (table 1) Colour Status Meaning Green Blink Frequency proportional to the power read by way of the CTs Not used Green Blink ZigBee communication: device not paired with the network Green Permanently alight ZigBee communication: device paired correctly with the network Green Permanently alight Power supply...
  • Seite 16: Technical Specifications

    All models comply with Directives 2014/30/UE (EMC), 2014/35/UE (LVD) e 2014/53/UE (RED). The appliance (or product) is subject to sorted collection, in compliance with local regulations on waste disposal currently in force. The Astrel Group hereby declares that this product is in compliance with essential requirements and other pertinent provisions established under Directive 2014/53/UE (RED).
  • Seite 17: 11. Installation Diagrams

    11. Installation diagrams Energy Meter for monitoring power drawn by load (fig. 3) Main meter Generation meter L1 L2 L3 N L1 L2 L3 N Elios4you Pro + Pro Smart Main switch Electrical load Wireless connection Green dot and direction of arrow K ...
  • Seite 18: Energy Meter Connected To Transfer Meter (Fig. 4)

    Energy Meter connected to transfer meter (fig. 4) Main meter Generation meter Green dot and direction of arrow K  L L1 L2 L3 N toward main switch L1 L2 L3 N Main switch User Elios4you Pro + Pro Smart Wireless connection Energy Meter 3~ RC L1 L2 L3...
  • Seite 19: Energy Meter Connected To Production Meter (Fig. 5)

    Energy Meter connected to production meter (fig. 5) Main meter Generation meter Green dot and direction L1 L2 L3 N of arrow K  L toward main switch L1 L2 L3 N Elios4you Pro + Pro Smart Main switch User Wireless connection Energy Meter 3~ RC...
  • Seite 20: Manuel D'installation Et Mode D'emploi

    à garantir l’obtention des résultats escomptés pour chacun des produits. La responsabilité d’Astrel Group en ce qui concerne ses produits est régie par les conditions générales de vente Astrel Group (disponibles sur le site www.astrelgroup.com).
  • Seite 21: Premier Allumage

     Smart RC  « Ajoutez dispositif Smart RC »  « Lancer la procédure » et sélectionner le type de mesure à appliquer à Energy Meter RC (production/échange/autre) Pour plus d’informations : www.4-noks.com/tutorial Uniquement si Energy Meter RC est utilisé pour mesurer la puissance consommée par une charge (modalité Autre) : accédez à...
  • Seite 22: Comportement Led (Tableau 1)

    Comportement LED (tableau 1) Couleur État Signification Vert Clignotant Fréquence proportionnelle à la puissance lue à travers les TI Non utilisé Vert Clignotant Communication ZigBee : dispositif non couplé avec le réseau Vert Fixe Communication ZigBee : dispositif correctement couplé avec le réseau Vert Fixe Alimentation...
  • Seite 23: Spécifications Techniques

    Tous les modèles répondent aux directives 2014/30/UE (EMC), 2014/35/UE (LVD) e 2014/53/UE (RED). L’équipement (ou le produit) doit faire l’objet de tri sélectif, conformément aux réglementations locales en vigueur en matière d’élimination des déchets. Par la présente, Astrel Group déclare que ce produit est conforme aux exigences essentielles et aux autres dispositions pertinentes fixées par la directive 2014/53/UE (RED).
  • Seite 24: 11. Schémas D'installation

    11. Schémas d’installation Energy Meter pour le contrôle de la consommation de la charge (fig. 3) Compteur Compteur d’énergie échangée de production L1 L2 L3 N L1 L2 L3 N Elios4you Pro + Pro Smart Différentiel général Électroménager Connexion sans fil Point vert et flèche K ...
  • Seite 25: Energy Meter Connecté Au Compteur D'énergie Échangée (Fig. 4)

    Energy Meter connecté au compteur d’énergie échangée (fig. 4) Compteur Compteur d’énergie échangée de production Point vert et flèche K  L en direction L1 L2 L3 N du différentiel général L1 L2 L3 N Différentiel général Usager Elios4you Pro + Pro Smart Connexion sans fil Energy Meter 3~ RC L1 L2 L3...
  • Seite 26: Energy Meter Connecté Au Compteur De Production (Fig. 5)

    Energy Meter connecté au compteur de production (fig. 5) Compteur Compteur d’énergie échangée de production Point vert et flèche K  L L1 L2 L3 N en direction du différentiel général L1 L2 L3 N Elios4you Pro + Pro Smart Différentiel général Usager Connexion...
  • Seite 27: Installations- Und Bedienungsanleitung

    Benutzer die volle Verantwortung und jedes Risiko im Zusammenhang mit der Installation, Konfiguration und Verwendung der Produkte. Die Haftung der Astrel Group für die eigenen Produkte ist durch die allgemeinen Geschäftsbedingungen der Astrel Group (auf der Website www.astrelgroup.com einsehbar) geregelt.
  • Seite 28: Erstmalige Einschaltung

     Smart RC  „Smart RC Gerät hinzufügen“  „Vorgang starten“ und wählen Sie die dem Energy Meter RC zuzuweisende Zählung aus (Erzeugung/Austausch/Sonstiges). Weitere Informationen unter: www.4-noks.com/tutorial Nur bei Verwendung des Energy Meter RC für die Messung der von einer Last verbrauchten Leistung (Modus Sonstiges): Markieren Sie unter „Einstellungen“...
  • Seite 29: Led-Verhalten (Tab. 1)

    LED-Verhalten (Tab. 1) Farbe Status Bedeutung Grün Blinkend Frequenz proportional zu der über die TA abgelesenen Leistung Nicht verwendet Grün Blinkend ZigBee-Kommunikation: Gerät nicht mit dem Netz gekoppelt Grün Permanent ZigBee-Kommunikation: Gerät mit dem Netz gekoppelt Grün Permanent Netzanschluss Grün Blinkend Übertragung der Informationen an das System Elios4you [Pro] Smart Permanent...
  • Seite 30: Technische Daten

    Alle Modelle entsprechen den Richtlinien 2014/30 EG (EMC), 2014/35 EG (LVD) und 2014/53 EG (RED). Gerät (oder Produkt), das nach den geltenden Bestimmungen zur Abfallentsorgung getrennt gesammelt werden muss. Hiermit erklärt Astrel Group, dass dieses Produkt den Min- destanforderungen und den anderen Vorschriften der Richtlinie 2014/53/EG (RED) entspricht. Die Konformitätserklärung ist auf der Website www.astrelgroup.com einsehbar.
  • Seite 31: 11. Installationspläne

    11. Installationspläne Energy Meter für die Verbrauchsüberwachung der Last (Abb. 3) Zweirichtungszähler Verbrauchszähler L1 L2 L3 N L1 L2 L3 N Elios4you Pro + Pro Smart Hauptschalter Haushaltsgerät WLAN- Verbindung Grüner Punkt und Richtung des Pfeils K  L zum Hauptschalter Energy Meter 3~ RC L1 L2 L3...
  • Seite 32: Energy Meter Mit Anschluss An Den Zweirichtungszähler (Abb. 4)

    Energy Meter mit Anschluss an den Zweirichtungszähler (Abb. 4) Zweirichtungszähler Verbrauchszähler Grüner Punkt und Richtung des Pfeils K  L L1 L2 L3 N zum Hauptschalter L1 L2 L3 N Hauptschalter Benutzer Elios4you Pro + Pro Smart WLAN-Verbindung Energy Meter 3~ RC L1 L2 L3...
  • Seite 33: Energy Meter Mit Anschluss An Den Erzeugungszähler (Abb. 5)

    Energy Meter mit Anschluss an den Erzeugungszähler (Abb. 5) Zweirichtungszähler Verbrauchszähler Grüner Punkt und Richtung L1 L2 L3 N des Pfeils K  L zum Hauptschalter L1 L2 L3 N Elios4you Pro + Pro Smart Hauptschalter Benutzer WLAN- Verbindung Energy Meter 3~ RC L1 L2 L3...
  • Seite 34: Note / Notes / Notes / Anmerkungen

    Note / Notes / Notes / Anmerkungen...
  • Seite 36 4-NOKS is a brand of ASTREL GROUP ASTREL GROUP SRL Via Isonzo, 21/E 34070 Mossa (GO) Italy www.astrelgroup.com www.4-noks.com +05T408950R2.0 Energy Meter 3RC Instruction manual_IT-EN-FR-DE 2018.07.09...

Inhaltsverzeichnis