Position
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
14
Designation
Inlet connection, drilled hole for float valve
Flange connection for inlet (diaphragm valve)
Draw-off connection
Evacuation connection
Water level indicator clear-view tube
Water level indicator screwed connection
Overflow
Ventilation and exhaust
Flush connection
Cover with locking ring for inspection open-
ing
Low water float switch
Connection socket for float switch
Float switch switching point Up
Float switch switching point Down
Moulded part connection water level indica-
tor
Float valve
16-1 Float ball
16-2 Lever arm
16-3 Counter nut
16-4 Valve body
Screwed connection
Check valve
T-piece
Fixation/pipe clamp
Diaphragm valve
Control line
Check valve
Pilot valve
Overflow shutter
Collection housing
Drain pipe with plug coupler
Flexible connection line
Pressure boosting system
Compensator
Base pedestal/height compensation
Automatic flushing device