Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance And Cleaning Instructions; Air Filter - Hoshizaki HNC-120BE-L-B Bedienungsanleitung

Thekenschaukasten
Vorschau ausblenden Andere Handbücher für HNC-120BE-L-B:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 16
7. The maximum safe height for displaying food
products is 9 cm above the interior bottom.
Food products should not be placed above this
height as they may not remain cold enough to
avoid spoilage.
8. If the showcase is turned off, wait for at least
3 minutes before restarting the showcase.
Otherwise the thermal motor protector may
operate and allow defrost water to drip onto
the items inside. The thermal motor protector
will reset automatically in 30 minutes.
9. To prevent damage to the glass parts, do not
place or hit any tableware,
bottles or edged tools directly
on the glass surfaces. Even a
tiny flaw may grow into a crack
(a few days) later.
10. To avoid entrance of vermin
during operation, the two drain
outlets, on the right and left
under the food mounts must
always have the drain plugs
fitted.
1) Clean inside the showcase.
2) Plug in the showcase, and turn on the circuit
breaker.
* When not in use, dry the showcase thoroughly and
store it in a dry place.
III. MAINTENANCE AND CLEANING
INSTRUCTIONS
IMPORTANT
1. Before carrying out any cleaning or maintenance
operations, unplug the showcase.
2. Do not disassemble the showcase further than
illustrated in Fig. 1.
3. Do not touch or wet the machine compartment
parts. This could result in failure or breakdown.
4. To prevent possible damage, do not clean the
plastic parts with water above 40°C or in a
dishwasher.
1. INTERIOR/EXTERIOR
* Clean the interior and food mounts every day for
sanitary use.
* Clean off the exterior with a soft cloth soaked in warm
water containing a neutral cleaner and wrung dry. Do
not use a water jet to clean the exterior.
* Use only a neutral cleaner. Other chemical agents
might cause damage to the interior and exterior
surfaces.
Note: To prevent damage to the part surfaces and the
coating on the evaporator, do not use a scourer
on the interior/exterior surfaces.
2. DRAIN PIPE CLEANING
1) Either mix 1 liter of water with 3.7 ml of 5.25%
sodium hypochlorite solution in a suitable container,
or the recommended Hoshizaki sanitizer as directed.
2) Disconnect the hose from the joint.
3) Turn up the end of the two joints .
4) Slowly pour the sanitizing solution into the drain
water circuit from the joints.
5) Wait for 5 minutes, and turn down the end of the
joints to drain the solution.
6) Leave the drain water circuit to dry out.

3. AIR FILTER

A plastic mesh air filter removes dirt or dust from the
air, and keeps the condenser from getting clogged. If
the filter gets clogged, the showcase's performance
will be reduced. Check the filter at least twice a month.
When clogged, use warm water and a neutral cleaner
to wash the filter.
1) Hold the tabs located at the bottom of the louver,
and lift them up to release the louver from the body.
2) Pull the louver toward you.
3) Pull out the louver downward.
4) Grasp the frame of the air filter, and pull it toward
you.
5) Clean the air filter.
6) Refit the air filter and louver in the reverse order of
the removal procedure.
5
ENGLISH

Werbung

Inhaltsverzeichnis
loading